Temperature Rise Comparison of Switchgear in SF6, N2, and Air

نویسندگان

  • Feng Hao
  • Zhang Junmin
چکیده

Based on the heat conduction equation, fluid flow governing equation and radiation heat transfer equation, a multi-physics coupled mathematical model is established, the convection heat transfer problem between solid and fluid is solved by wall function. The three dimensional thermal field in a type of switchgear filled respectively with SF6, N2, and air are calculated and analyzed to discuss the feasibility of using air or N2 as the substitution of SF6 by the finite volume method. The results show that the temperature fields in three gases are similar in the switchgear. The temperature rise of current-carrying loop is the highest in SF6 and is the lowest in the air. So the conclusion could be made that air or N2 can replace SF6 as the insulating gas of switchgear on the perspective of temperature rise.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dielectric Properties of Gases Suitable for Secondary Medium Voltage Switchgear

SF6 is the dominating technology for gas insulated switchgear due to its excellent dielectric, thermal and arc quenching properties. Unfortunately, SF6 suffers from a very high global warming potential (GWP). Even though medium voltage switchgear is sealed for life with less than 0.1% emissions per year, the EU has specifically targeted SF6 for replacement in medium voltage switchgear for secon...

متن کامل

Critical electric field strength and effective ionization coefficient measurements of nitrogen-oxygen mixtures with variable mixing ratio

Air is the most commonly used insulation gas in high voltage applications: Mostly ambient air for overhead power lines and air insulated substations, but also synthetic air in medium voltage metalenclosed switchgear at slightly elevated pressures. Moreover, nitrogen and air have been proposed as suitable alternatives to SF6 in high-voltage insulation and interruption applications of gas insulat...

متن کامل

Investigating Characteristics of N2, CO2 and CF3I in Contrast to High Current Arcs in Circuit Breakers to Choose a Suitable Substitute for SF6

Specific and sensitive operation of circuit breakers makes an individual position for them in power networks. Circuit breakers are at the central gravity of variations and execution operations. Therefore, an optimum operation is the main reason to investigate about new gases to be used in MV and HV circuit breakers instead of SF6. The arc process has enormous complexity because of hydrodynamic ...

متن کامل

Inactivation of Gram-Negative Bacteria by Low-Pressure RF Remote Plasma Excited in N2-O2 Mixture and SF6 Gases

The role of low-pressure RF plasma in the inactivation of Escherichia coli O157, Klebsiella pneumoniae, Proteus mirabilis, and Enterobacter sakazakii using N2-O2 and SF6 gases was assessed. 1×109 colony-forming units (CFUs) of each bacterial isolate were placed on three polymer foils. The effects of pressure, power, distance from the source, and exposure time to plasma gases were optimized. The...

متن کامل

Development of Medium-voltage Switchgear for Reducing Environmental Impact and Space-saving

Kenji Tsuchiya Koichi Nagano Ayumu Morita Tetsuya Hirao OVERVIEW: To make medium-voltage switchgear (52 kV or less) smaller and more robust, there has been a shift away from AISs and toward GISs that use SF6 gas . However, the high global warming coefficient of SF6 gas means it was designated as a greenhouse gas by the Kyoto Protocol (Kyoto Protocol to the United Nations Framework Convention on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013