Fast-FISH technique for rapid, simultaneous labeling of all human centromeres.

نویسندگان

  • M Durm
  • I Sorokine-Durm
  • F M Haar
  • M Hausmann
  • H Ludwig
  • P Voisin
  • C Cremer
چکیده

Fluorescence in situ hybridization (FISH) has become a powerful tool in chromosome analysis. This report describes the systematic optimization of the Fast-FISH technique for centromere labeling of human metaphase chromosomes for radiobiological dosimetry purposes. For the present study, the hybridization conditions and the efficiency of two commercially available alpha-satellite DNA probes were compared ("human chromosome 1 specific", Oncor, Gaithersburg, MD, vs. "all-human chromosomes specific", Boehringer-Mannheim, Germany). These probes were hybridized to human lymphocyte metaphase plates by using a hybridization buffer without formamide and without any other equivalent denaturing chemical agents. The results indicate the suitability of the method for automated image analysis on the basis of thresholding. The optimal conditions concerning hybridization time and temperature were determined by a systematic quantitative evaluation of the fluorescent labeling sites after the hybridization procedures. Under defined "low stringency" conditions, we found that the "human chromosome 1 specific" DNA probe labeled not only the centromere of the human chromosome 1 but also the other human centromeres in the same way as the "all-human chromosome specific" DNA probe. The optimized conditions to complete all centromere labeling were applied to the detection of dicentric chromosomes on irradiated human lymphocyte samples (gamma-rays of 60Co source, 0.5 Gy/min, for doses of 1, 3, and 4 Gy). The yield of dicentrics was determined after Fast-FISH and compared with results obtained after Giemsa staining. These results are very compatible and indicate that, because of its simplicity, this optimized Fast-FISH procedure would be useful for fast screening purposes in biological dosimetry after accidental overexposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mutation Induction by Ionizing Radiation

Fluorescence in situ hybridization (FISH) has opened new perspectives for the identification and classification of radiation induced chromosome aberrations. Selective staining of individual human chromosomes by chromosome painting allows a rapid microscopic observation of dicentric and translocation chromosomes. Methods of automated digital image analysis accelerate the evaluation of FISH label...

متن کامل

A straightforward DOPE (double labeling of oligonucleotide probes)-FISH (fluorescence in situ hybridization) method for simultaneous multicolor detection of six microbial populations.

Fluorescence in situ hybridization (FISH) with rRNA-targeted oligonucleotide probes is an essential tool for the cultivation-independent identification of microbes within environmental and clinical samples. However, one of the major constraints of conventional FISH is the very limited number of different target organisms that can be detected simultaneously with standard epifluorescence or confo...

متن کامل

Development of a Rapid Derivative Spectrophotometric Method for Simultaneous Determination of Acetaminophen, Diphenhydramine and Pseudoephedrine in Tablets

A mixture of acetaminophen, diphenhydramine hydrochloride and pseudoephedrine hydrochloride is used for the symptomatic treatment of common cold. In this study, a derivative spectrophotometric method based on zero-crossing technique was proposed for simultaneous determination of acetaminophen, diphenhydramine hydrochloride and pseudoephedrine hydrochloride. Determination of these drugs was perf...

متن کامل

Development of a Rapid Derivative Spectrophotometric Method for Simultaneous Determination of Acetaminophen, Diphenhydramine and Pseudoephedrine in Tablets

A mixture of acetaminophen, diphenhydramine hydrochloride and pseudoephedrine hydrochloride is used for the symptomatic treatment of common cold. In this study, a derivative spectrophotometric method based on zero-crossing technique was proposed for simultaneous determination of acetaminophen, diphenhydramine hydrochloride and pseudoephedrine hydrochloride. Determination of these drugs was perf...

متن کامل

Fetal aneuploidy diagnosis through rapid fluorescence in situ hybridization (FISH) on uncultured amniocytes Diagnosticul aneuploidiilor fetale prin hibridizarea fluorescenta in situ (FISH) rapidă a amniocitelor necultivate

Rapid prenatal diagnostic tests are now increasingly popular, either as a stand-alone test or associated with conventional karyotype. Their main advantages are maternal anxiety relief and low cost. However, the results are available in more than 48 hours from amniocentesis. We present a rapid fluorescence in situ hybridization (FISH) technique, modified to give prenatal diagnostic results in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cytometry

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 1998