Prevention of ventricular tachycardia induction during right ventricular programmed stimulation by high current strength pacing at the site of origin.
نویسندگان
چکیده
To determine whether high current strength pacing at the site of origin of ventricular tachycardia (VT) could prevent induction of VT, we studied 11 VTs in 10 patients with chronic coronary artery disease. The left ventricular site of origin of all VT was determined by endocardial catheter mapping. Reproducible VT induction from the right ventricular apex or outflow tract was demonstrated with a pacing current strength equal to twice diastolic threshold (less than or equal to 2.0 mA) with single (two VTs), double (eight VTs), or triple (one VT) extrastimuli following 8 beats of a drive cycle length of 400 to 600 msec. After determination of the baseline VT induction zone (range 10 to 80 msec), repeat induction was attempted while simultaneous pacing was performed during the 8 beat drive train from the left ventricular site of origin with the use of a high current strength (10 mA [two VTs] or 20 mA [nine VTs]) and from the baseline right ventricular site with a current strength equal to twice diastolic threshold. Extrastimuli were introduced only from the right ventricular site over the same range of coupling intervals that resulted in VT initiation during the baseline state. In five of the 11 trials, no VT could be initiated; in one trial, the VT induction zone was decreased from 80 to 10 msec; in three trials, only VT of a different morphology and a distinct (greater than 4 cm distant) site of origin was initiated; and in two trials, VT of the same morphology was initiated. In four of the five trials in which all VT was prevented by simultaneous pacing with a high current strength at the site of origin, simultaneous pacing at a lower current strength (twice diastolic threshold) at the site of origin (three VTs) or with equally increased current strength (10 to 20 mA) at nonsites of origin (two VTs) did not prevent initiation. We conclude that: high current strength pacing at the site of origin during the drive train can inhibit VT induction with extrastimuli and, successful prevention of VT may depend on the pacing site being the site of origin and the current strength used during pacing.
منابع مشابه
THERAPY AND PREVENTION ARRHYTH]IIA Prevention of ventricular tachycardia induction during right ventricular programmed stimulation
To determine whether high current strength pacing at the site of origin of ventricular tachycardia (VT) could prevent induction of VT, we studied 11 VTs in 10 patients with chronic coronary artery disease. The left ventricular site of origin of all VT was determined by endocardial catheter mapping. Reproducible VT induction from the right ventricular apex or outflow tract was demonstrated with ...
متن کاملA prospective comparison of triple extrastimuli and left ventricular stimulation in studies of ventricular tachycardia induction.
One hundred and one patients with sustained unimorphic ventricular tachycardia underwent programmed ventricular stimulation with one of two protocols. Fifty patients underwent programmed stimulation with protocol A, which consisted of burst overdrive pacing, single, double, and triple extrastimuli at the right ventricular apex, right ventricular outflow tract, or septum, and then at the left ve...
متن کاملSequelae of nonsustained polymorphic ventricular tachycardia induced during programmed ventricular stimulation.
The results of 206 programmed ventricular stimulation studies performed in 130 patients (100 men and 30 women, mean age 62 +/- 12 years, +/- standard deviation) were examined prospectively to determine the sequelae of nonsustained polymorphic ventricular tachycardia (VT) induced during programmed ventricular stimulation. The clinical indication for the electrophysiologic study was either docume...
متن کاملEffects of high stimulation current on the induction of ventricular tachycardia.
Programmed stimulation at 2 right ventricular sites with 1 to 3 extrastimuli was performed at current strengths of twice diastolic threshold (1.0 +/- 0.2 mA, mean +/- standard deviation) and 10 mA in 41 patients undergoing an electrophysiologic study because of sustained ventricular tachycardia (VT) (11 patients), nonsustained VT (19 patients) or unexplained syncope (11 patients). In 26 patient...
متن کاملDIAGNOSTIC METHODS ELECTROPHYSIOLOGY Comparison of bipolar and unipolar programmed electrical stimulation for the initiation of ventricular arrhythmias: significance of anodal excitation during bipolar stimulation
To determine if anodal excitation during bipolar stimulation facilitates the initiation of sustained monomorphic ventricular tachycardia, nonsustained polymorphic ventricular tachycardia, or repetitive ventricular responses, both bipolar and cathodal unipolar programmed ventricular stimulation with one to three extrastimuli delivered during ventricular pacing at two rates from the right ventric...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 76 2 شماره
صفحات -
تاریخ انتشار 1987