Comparison of Corded and Cordless Handpieces on Forearm Muscle Activity, Procedure Time and Ease of Use during Simulated Tooth Polishing.
نویسندگان
چکیده
PURPOSE Dental professionals suffer from a high prevalence of work-related musculoskeletal disorders (MSD). Dental hygienists in particular have a high prevalence of pain in the forearms and hands. The objective of this study was to compare 1 cordless handpiece to 2 corded handpieces during simulated tooth polishing in terms of the muscle loads (recorded as electromyography (EMG) activity), duration of polishing procedure, and dental hygienist opinion about ease of use. METHODS EMG was used to quantify muscle electrical activity of 4 forearm muscles during simulated dental polishing with 2 corded handpieces (HP-A and HP-B) and 1 cordless handpiece (HP-C). A convenience sample of 30 dental hygienists (23 to 57 years of age) with 1 to 20+ years of clinical practice experience completed the study. Each participant spent approximately 5 minutes polishing 3 predetermined teeth in each of the 4 quadrants. The sequence of the handpieces was randomly assigned. At the end of the study, participants completed a subjective end user evaluation of handpiece preference. RESULTS Muscle activity levels of 10th, 50th and 90th percentiles did not differ significantly between the 3 handpieces tested (p>0.05). However, total muscle workload (integrated EMG) was lowest for the cordless handpiece (HP-C), but this was only significantly less than HP-A (p<0.05). Polishing using the cordless handpiece (HP-C) (M=257 seconds, SD=112 seconds) took significantly less time than either the HP-A corded (M=290 seconds, SD=137 seconds) or HP-B corded handpiece (M=290 seconds, SD=126 seconds) (p<0.05). Overall, 50% of the study participants preferred the cordless handpiece, 37% preferred HP-A and 13% preferred HP-B (p<0.05). CONCLUSION Use of the cordless handpiece reduced the duration of polishing, which in turn led to less total muscle activity, but not muscle intensity. Overall, dental hygienists preferred the cordless handpiece.
منابع مشابه
مقایسه میزان تطابق لبهای بین پرداخت فوری و تأخیری درترمیمهای گلاس آینومر و کامپوزیت توسط میکروسکوپ الکترونی
Background and Aims: Marginal seal in class V cavities and determining the best restorative material to decrease microleakage is of great importance in operative dentistry. The aim of this study was to evaluate the effect of polishing time on the microleakage of three types of tooth-colored restorative materials in class V cavity preparations and to assess the marginal integrity of these materi...
متن کاملIs Abdominal Muscle Activity Different from Lumbar Muscle Activity during Four-Point Kneeling?
Background: Stabilization exercises can improve the performance of trunk and back muscles, which are effective in the prevention and treatment of low back pain. The four-point kneeling exercise is one of the most common types of stabilization exercises. This quasi-experimental study aimed to evaluate and compare the level of activation between abdominal and lumbar muscles in the different stage...
متن کاملEffect of Finishing and Polishing Time, Technique and Surface Coating on Microleakage of Encapsulated Restorative Resin Modified Glass Ionomer: An In Vitro Study
Background and Aim: This study aimed to assess the effect of finishing and polishing time, technique and surface coating on microleakage of encapsulated restorative resin modified glass ionomer (RMGI). Materials and Methods: In this in vitro study, 40 freshly extracted human premolars were selected. Two standard class V cavities were prepared on the buccal and lingual surfaces of each tooth. T...
متن کاملVariation in the forearm extensor muscle: case report
Background: The Extensor Carpi Radialis Longus (ECRL) and the Extensor Carpi Radialis Brevis (ECRB) are muscles of the posterior forearm compartment. variations in this area of the forearm are common and are usually diagnosed during surgery. Sometimes these variations are symptomatic and can be helpful in clinical procedures such as surgery. Diagnosis and identification of abnormalities can be ...
متن کاملEffect of Genu Varum Deformity on Gluteus Medius Muscle Activity and Postural Control During Single-Leg Jump-Landing
Purpose: Genu varum deformity changes the line of gravity from center of knee towards the medial side. This deviation results in changes in the upper part of the lower extremity that can affect postural control as well as the position and activity of the proximal muscles of the knee joint, like the gluteus medius muscle. Therefore this study aims to investigate the effect of genu varum disorder...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of dental hygiene : JDH
دوره 88 6 شماره
صفحات -
تاریخ انتشار 2014