Proton Radiography study using a passive scattered beam
نویسندگان
چکیده
The use of high-energy proton beams enables to delivering high doses to target volumes, while sparing organs at risk compared to X-ray radiotherapy. However, the protons advantages cannot be fully exploited because the range (i.e the stopping powers) of protons in matter is not accurately known. Indeed, the proton stopping powers are obtained by an empirical conversion of X-CT Hounsfield Units that leads to systematic errors in proton range calculation. Several publications demonstrated that proton imaging was feasible and could be used to directly obtain proton stopping powers. However, the main drawback of p-CT or proton radiography (p-RG) is the limited spatial resolution, induced by the multiple Coulomb scattering of protons with nuclei.
منابع مشابه
Calculation of Neutron Dose Ratio of Heart, Lung and Liver due to breast cancer Proton Therapy using MCNPX code
Introduction: The proton beam produced in particle accelerators has an appropriate therapeutic potential. In this research, proton therapy of breast cancer is simulated using the MCNPX code in a MIRD phantom, also the contribution of scattered neutron dose during the proton therapy were calculated for the Heart, Lung and Liver. Materials and Methods: For si...
متن کاملProton Therapy of eye using MCNPX code
Introduction: Proton radiotherapy is the one of advanced teletherapy methods. The protons deposit their maximum energy in a position called Bragg peak. Therefore, for treatment of cancer, the tumor should be placed at the Bragg peak or SOBP. The scattered photons and neutrons is a challenge in proton radiotherapy. The aim of this study is calculation of absorbed dose from scatt...
متن کاملTime‐resolved diode dosimetry calibration through Monte Carlo modeling for in vivo passive scattered proton therapy range verification
PURPOSE Our group previously introduced an in vivo proton range verification methodology in which a silicon diode array system is used to correlate the dose rate profile per range modulation wheel cycle of the detector signal to the water-equivalent path length (WEPL) for passively scattered proton beam delivery. The implementation of this system requires a set of calibration data to establish ...
متن کاملImpact of Various Beam Parameters on Lateral Scattering in Proton and Carbon-ion Therapy
Background: In radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. Heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness.Methods: In this study, we used Monte Carlo method-based Geant4 toolkit to s...
متن کاملInvestigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study
Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...
متن کامل