Quadrupole and Sextupole for Dual Bore Ring

نویسنده

  • A. Mikhailichenko
چکیده

Latest results of testing the compact dual bore quadrupole and sextupole represented. Dual bore quadrupole tested in cryostat up to ~150 A feeding current generating ~1 kG/cm in each aperture. Sextupole was tested in Dewar and able to generate ~0.7 kG/cm of integrated field. Transverse size of the magnets cold masses is about 180 mm. Dual bore water cooled room temperature apertures are 54 mm in diameter each and the distance between centers of these apertures is 79 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Field Magnets with High Temperature Superconductors for an Upgrade of Cesr*#

An upgrade to the CESR electron-positron storage ring is being considered in which the single ring machine is replaced with two rings capable of storing high currents to provide high luminosity symmetric electron-positron collisions. This paper considers the implementation of the two rings using dual bore quadrupoles fabricated with high temperature superconductors (HTS). The use of HTS provide...

متن کامل

Preliminary Change Request for the Chromatic Sextupoles and Trim Quadrupole Elements of the SNS Accumulator Ring

In view of the adopted modi ed design for the 1.3 GeV compatible accumulator ring of the SNS [1], complementary studies have been undertaken, in order to justify the need of higheld chromatic sextupoles for chromaticity correction. Furthermore, as these chromatic sextupoles introduce a rst order quadrupole \feed-down" e ect, the trim quadrupole elements speci cations had to be reviewed in order...

متن کامل

Effect of Vacuum Chamber Eddy Current and Compensation by Digital Feedback

Measurement of the effect of the eddy current induced in the APS storage ring vacuum chamber by the storage ring sextupole magnet and its compensation using digital feedback with proportional, integral, and derivative (PID) control algorithm are presented. The magnetic field in the vacuum chamber shows strong quadrupole and sextupole components varying with frequency, in addition to significant...

متن کامل

Some Features of Superconducting Dual Bore Lens

* Work supported by National Science Foundation † Phone: (607) 255-3785, Fax: (607) 255-8062, e-mail: [email protected] Abstract Design of dual bore superconducting quadrupole for CESR upgrade is represented. The lens has a gradient about 1 kG/cm, dual aperture of 54 mm each, length about 800 mm, The axes spacing about 80 mm allows a good separation of counter rotating beams. Harmon...

متن کامل

Development of Recondensing Cryostat for PAMELA

PAMELA (Particle Accelerator for MEdicaL Applications) is a design study of a novel accelerator for cancer therapy using protons and carbon ions. The accelerator utilizes the nonscaling Fixed Field Alternating Gradient (FFAG) principle and features superconducting combined-function magnets with dipole, quadrupole, sextupole and octupole field components for steering the ion beam. The proton rin...