Ilc Beam Energy Measurement Based on Synchrotron Radiation from a Magnetic Spectrometer
نویسنده
چکیده
A magnetic spectrometer with a relative energy resolution of 5·10 was proposed for ILC beam energy calibration. A complementary method of beam energy measurement based on registration of synchrotron radiation (SR) from the dipole magnets of the energy spectrometer is proposed. Measuring both horizontal edge positions of the SR fan at a distance of 50-70 m downstream of spectrometer allows to determine the beam energy with high accuracy. The main principals of the SR beam energy measurement, first numerical simulations by means of GEANT and physical limitations of the detector coordinate determination are described. Two versions of novel detectors for low-energy (<20keV) photon registration are proposed. They are characterized by a high counting rate and a linear resolution of 2-3 μm.
منابع مشابه
Pulse-by-pulse Energy Measurement at the Stanford Linear Collider*
The Stanford Linear Collider (SLC) collides a beam of electrons and positrons at 92 GeV. It is the first colliding linac, and produces Zo particles for High-Energy Physics measurements. The energy of each beam must be measured to one part in lo4 on every collision (120 Hz). An Energy Spectrometer in each beam line after collision produces two stripes of highenergy synchrotron radiation with cri...
متن کاملMeasuring the Beam Energy with Radiative Return Events
The beam energy at the ILC is needed to a precision of around 10−4 for accurate mass determinations of the top quark, the Higgs boson and in supersymmetry [1]. This measurement will mainly be done with a magnetic spectrometer [2]. However the absolute calibration of such a spectrometer is difficult and in addition the luminosity weighted centre of mass energy is not necessarily identical to twi...
متن کاملCoherent Synchrotron Radiation Studies at the Accelerator Test Facility*
Coherent Synchrotron Radiation has been the object of recent experiments and is a topic of great importance for several accelerators currently in their design phase (LCLS, ILC, CIRCE). We present the results of several experimental sessions performed at the Accelerator Test Facility KEK (ATF). An infrared bolometer was used to detect the emitted synchrotron radiation in the 1 0.05 mm wavelength...
متن کاملA phase-space beam position monitor for synchrotron radiation
The stability of the photon beam position on synchrotron beamlines is critical for most if not all synchrotron radiation experiments. The position of the beam at the experiment or optical element location is set by the position and angle of the electron beam source as it traverses the magnetic field of the bend-magnet or insertion device. Thus an ideal photon beam monitor would be able to simul...
متن کاملDesign Studies and Sensor Tests for the Beam Calorimeter of the ILC Detector
The International Linear Collider (ILC) is being designed to explore particle physics at the TeV scale. The design of the Very Forward Region of the ILC detector is considered in the presented work. The Beam Calorimeter one of two electromagnetic calorimeters situated there is the subject of this thesis. The Beam Calorimeter has to provide a good hermeticity for high energy electrons, positrons...
متن کامل