Comparison of spiral and FLASH phase velocity mapping, with and without breath-holding, for the assessment of left and right coronary artery blood flow velocity.

نویسندگان

  • Jennifer Keegan
  • Peter D Gatehouse
  • Raad H Mohiaddin
  • Guang-Zhong Yang
  • David N Firmin
چکیده

PURPOSE To develop high temporal resolution coronary artery spiral phase velocity mapping sequences and to compare the results obtained with those from FLASH sequences. MATERIALS AND METHODS Velocity curves were obtained in eight left and eight right coronary arteries using breath-hold interleaved spiral (BH_SP), free-breathing interleaved spiral (FB_SP), breath-hold segmented FLASH (BH_FL), and free-breathing FLASH (FB_FL) sequences. Spatial resolution, temporal resolution, and acquisition durations (cardiac cycles) were as follows-BH_SP: 0.9 mm x 0.9 mm, 30 msec, 20 cycles; FB_SP: 0.9 mm x 0.9 mm, 42 msec, 100 cycles; BH_FL: 0.9 mm x 1.8 mm, 70 msec (effective), 20 cycles; FB_FL: 0.9 mm x 1.8 mm, 30 msec, 480 cycles. Peak systolic, peak diastolic, and mean velocities were compared between sequences. RESULTS For left and right arteries, the FB_SP velocity profiles closely followed those from the FB_FL sequence. By comparison, the BH_FL sequence failed to resolve the sharp peaks in the temporal velocity profiles of the right coronary artery, significantly underestimating the peak systolic (88 mm/second vs. 252 mm/second, P < 0.001), peak diastolic (114 mm/second vs. 153 mm/second, P < 0.01), and mean (56 mm/second vs. 93 mm/second, P < 0.001) velocities. For the less mobile left artery, the peak systolic, peak diastolic, and mean velocities were also underestimated by the BH_FL sequence, although this only reached statistical significance for the systolic peak (80 mm/second vs. 135 mm/second, P < 0.01), 142 mm/second vs. 168 mm/second, (P = ns), and 87 mm/second vs. 101 mm/second, (P = ns) respectively. CONCLUSION We have shown that the FB_SP sequence developed agrees well with the FB_FL sequence, while the study duration is reduced by a factor of 10 for the same spatial resolution. By comparison, the BH_FL sequence underestimates flow velocities, particularly in the more mobile right coronary artery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of high temporal resolution spiral phase velocity mapping of coronary artery blood flow against Doppler flow wire

Background The temporal pattern of coronary artery flow velocity through the cardiac cycle provides important information about coronary haemodynamics. The ‘gold standard’ for coronary artery velocity assessment is the Doppler flow wire which is inserted directly into the coronary artery under X-ray fluoroscopic guidance, which is invasive, uses ionising radiation and has a small but significan...

متن کامل

Inter breath-hold reproducibility of temporal patterns of coronary artery blood flow

Background While blood flow in the majority of arteries peaks in systole, the rhythmic squeezing of the coronary arteries and microcirculation as the heart beats results in left anterior descending artery (LAD) flow being diastolicpredominant while for the right coronary artery (RCA), there is approximately equal flow in systole and diastole. These temporal flow patterns can provide important i...

متن کامل

Validation of high temporal resolution spiral phase velocity mapping of temporal patterns of left and right coronary artery blood flow against Doppler guidewire

BACKGROUND Temporal patterns of coronary blood flow velocity can provide important information on disease state and are currently assessed invasively using a Doppler guidewire. A non-invasive alternative would be beneficial as it would allow study of a wider patient population and serial scanning. METHODS A retrospectively-gated breath-hold spiral phase velocity mapping sequence (TR 19 ms) wa...

متن کامل

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

Effect of Breath Holding on Blood Flow Measurement using Fast Velocity Encoded Cine MR Imaging

Introduction Velocity encoded tine (VEC) MR imaging provides quantitative assessment of blood flow in the cardiovascular system. With use of segmented k-space fast VEC MR imaging, noninvasive assessment of blood flow and vasodilator flow reserve in the coronary artery and coronary arterial bypass graft can be obtained within a single breath-hold time. However, it has been pointed out that blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2004