Accuracy of emergency physicians using ultrasound to determine gestational age in pregnant women.

نویسندگان

  • Sachita Shah
  • Nathan Teismann
  • Brita Zaia
  • Farnaz Vahidnia
  • Gerin River
  • Dan Price
  • Arun Nagdev
چکیده

INTRODUCTION Rapid and accurate determination of gestational age may be vital to the appropriate care of the critically ill pregnant patient. Before the use of emergency ultrasound, physical examination of fundal height (FH) in the nonverbal patient was considered the quickest method to estimate gestational age. We conducted a prospective, observational study of the performance of bedside sonography to determine gestational age. METHODS We enrolled a convenience sample of women in their second or third trimester of pregnancy. Emergency physicians (EPs) made ultrasound measurements of fetal biparietal diameter (BPD) and femur length, followed by a measurement of FH. These measurements were compared with true gestational age (TGA), sonography by an ultrasound technician, and measurement of FH performed by an obstetrician. Main outcome measures were the average time needed to complete measurements; correlation coefficients between EP measurements and those made by an ultrasound technician, an obstetrician, and TGA, and overall accuracy to determine fetal age greater than 24 weeks. RESULTS The average time to complete ultrasound measurements was less than 1 minute. When physician-performed measurements were compared with TGA, the correlation coefficients were 0.947 (0.926-0.968) for BPD, 0.957 (0.941-0.973) for femur length, and 0.712 (0.615-0.809) for FH. When determining fetal viability, EP's overall accuracy was 96% using ultrasound and 80% using FH. CONCLUSIONS With brief training, EPs can quickly and accurately determine gestational age using ultrasound, and these estimates may be more accurate than those obtained through physical examination. Emergency physicians should consider using ultrasound in emergent evaluation of pregnant patients who are unable to provide history.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of emergency physician performed bedside ultrasound in determining gestational age in first trimester pregnancy

UNLABELLED BACKGROUND Patient reported menstrual history, physician clinical evaluation, and ultrasonography are used to determine gestational age in the pregnant female. Previous studies have shown that pregnancy dating by last menstrual period (LMP) and physical examination findings can be inaccurate. An ultrasound performed in the radiology department is considered the standard for determ...

متن کامل

Comparative Assessment of Ultrasound Placental Findings in Small for Gestational Age and Normal-Weight Fetuses

Background Small for gestational age (SGA) refers to newborns whose birth weight is less than the 10th percentile for gestational age. The aim of this study was to provide a comparative assessment of ultrasound placental findings in SGA and normal-weight fetuses in singleton pregnant women. Materials and Methods In...

متن کامل

Comparison of the first trimester ultrasound and Parikh’s formula in determining the expected date of delivery: A prospective study

Introduction: The Parikh’s formula is a calculation method that considers menstrual cycle duration in women who have an unusual interval of menstruation cycle. Since the accurate estimation of gestational age affects pregnancy outcomes, the present study aimed to compare the first trimester ultrasound and Parikh’s formula in determining the Expected Date of Delivery (EDD). Mate...

متن کامل

بررسی اختلالات مادرزادی بوسیله سونوگرافی معده جنین

Ultrasound study of fetal stomach is multidirectionally rewarding . It can be used to detect congenital aberrations and to estimate gestational age in comparison with biparietal diamater (BPD). This study was performed in 60 pregnant women in 14-40 weeks of gestation. Maximum width and lengths of fetal stomach were measured and compared with BPD in order to determine gestational age . In 4 fetu...

متن کامل

دقت سونوگرافی جهت تخمین وزن هنگام تولد

Background and purpose: Âccurate estimation of fetal weight is of paramount importance in the management of labor and delivery and may be related to critical points of decision making and proper management. This study was done in order to compare the accuracy of clinical and ultrasonic estimation of fetal weight in Ïmam Khomeini hospital of Sari, Ïran. Materials and methods: During this st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of emergency medicine

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 2010