Asymmetric real-time PCR detection of BRCA1 5382insC mutation by melting curve analysis in the LightCycler.
نویسندگان
چکیده
BACKGROUND 5382insC BRCA1 frameshift mutation is a common founder mutation for many populations worldwide and a high-risk allele for the development of hereditary breast and/or ovarian cancer. Our goal was to develop a novel, reliable and rapid method for its detection. METHODS We developed an asymmetric real-time PCR method with hybridization probes in the LightCycler. Genotyping was performed by melting curve analysis. RESULTS AND CONCLUSIONS The developed method was in concordance with reference methods when tested in 85 peripheral blood and 107 tumor DNA samples from Greek breast and/or ovarian cancer patients. The described method proved to be simple, cost-effective, easy to perform and rapid enough for routine use as a screening method in high-risk families and especially in the Greek, Slavic and Jewish populations where 5382insC mutation is the most common BRCA1 mutation.
منابع مشابه
BRCA1 and BRCA2 mutation screening using SmartCycler II high-resolution melt curve analysis.
CONTEXT Real-time polymerase chain reaction technologies have replaced many of the more labor-intense methods in the molecular diagnostics laboratory. Similarly, melt curve analysis can provide a rapid means of mutation screening. OBJECTIVE To determine if real-time polymerase chain reaction and melt curve analysis using the SmartCycler II could be used as a screening tool for 3 common mutati...
متن کاملQuantification and Optimization of Candida albicans DNA in Blood Samples Using Real- Time PCR
Background: Candida albicans (C. albicans) is a major cause of candidaemia in people with impaired immunity. Blood culture is a “gold standard” for candidaemia detection but is time-consuming and relatively insensitive. We established a real-time PCR assay for C. albicans detection in blood by LightCycler PCR and melting curve analysis. Methods: Five milliliter blood samples from...
متن کاملHigh-resolution melting curve analysis on the LightCycler® 480 PCR system
480 PCR system Roche Applied Science ́s LightCycler® family of real-time PCR systems offer fast, accurate and versatile platforms for genetic variation research. The new plate-based LightCycler® 480 System provides the temperature homogeneity and optical characteristics required for high-performance melting-curve analysis (MCA). On the level of data acquisition and available detection channels, ...
متن کاملDevelopment and Inter-Laboratory Validation of Unlabeled Probe Melting Curve Analysis for Detection of JAK2 V617F Mutation in Polycythemia Vera
BACKGROUND JAK2 V617F, a somatic point mutation that leads to constitutive JAK2 phosphorylation and kinase activation, has been incorporated into the WHO classification and diagnostic criteria of myeloid neoplasms. Although various approaches such as restriction fragment length polymorphism, amplification refractory mutation system and real-time PCR have been developed for its detection, a gene...
متن کاملClinical applications of whole-blood PCR with real-time instrumentation.
BACKGROUND As the genetic basis of many human diseases is being discovered, there is increasing need for the detection of single-nucleotide polymorphisms/mutations in medical laboratories. We describe an innovative approach that combines PCR amplification directly on whole blood and real-time detection PCR technology (WB-RTD PCR). METHODS We compared WB-RTD PCR with the method for extracted D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinica chimica acta; international journal of clinical chemistry
دوره 390 1-2 شماره
صفحات -
تاریخ انتشار 2008