Development and validation of UPLC method for simultaneous estimation of Efavirenz and Lamivudine in pharmaceutical formulations
نویسندگان
چکیده
Article history: Received on: 11/01/2016 Revised on: 09/02/2016 Accepted on: 04/03/2016 Available online: 30/03/2016 An accurate and precise UPLC method was developed for the simultaneous estimation of efavirenz and lamivudine in pharmaceutical dosage forms. The chromatographic analysis was performed on Acquity UPLC BEH Shield RP18 (50 × 3 mm, 1.7 μm) column with mobile phase consisting of 10% acetonitrile in methanol and 10 mM phosphate buffer (pH 4.0) in the gradient mode, at a flow rate of 0.4 mL/min, and eluents monitored at 254 nm. The calibration curves of peak area versus concentration, which was linear from 10-60 μg/mL for efavirenz and 5.0-30 μg/mL for lamivudine, had regression coefficient (r 2 ) greater than 0.999. The method had the requisite accuracy, precision, and robustness for simultaneous determination of efavirenz and lamivudine in tablets. The proposed method is simple, economical, accurate, and precise and could be successfully employed in routine quality control for the simultaneous analysis of efavirenz and lamivudine in pharmaceutical formulations.
منابع مشابه
HPTLC-densitometry method development and validation for simultaneous determination of abacavir, lamivudine and zidovudine in combined dosage form
A simple, accurate and precise HPTLC- densitometry method for the simultaneousdetermination of abacavir, lamivudine and zidovudine in pharmaceutical tablet has beendeveloped. Separation of tablet components was performed on aluminum backed HPTLC plates(silica gel 60 F254 20×20 cm with 0.2 mm thickness, Camag, Muttenz, Switzerland ) usingmethanol : chloroform : acetonitrile (4 : 8 : 3 v/v). Good...
متن کاملDevelopment and Validation of a Rp-hplc Method for Simultaneous Estimation of Lamivudine, Tenofovir Disoproxil Fumarate and Efavirenz in a Combined Tablet Dosage Form
Objective: Development of an accurate, simple, precise and rapid method for estimating Tenofovir disoproxil fumarate, Lamivudine and Efavirenz simultaneously, in a combined tablet form. Methods: The method uses Reverse Phase High Performance Liquid Chromatography (RP-HPLC). Symmetry C18 (4.6 x 100 mm, 3.5 μm) column operated with a mixture of phosphate buffer of pH 4.0 with ortho phosphoric aci...
متن کاملA New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...
متن کاملSimultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form
The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...
متن کاملSimultaneous Spectrophotometric Estimation of Tenofovir Disoproxil Fumarate and Lamivudine in Three Component Tablet Formulation Containing Efavirenz
Three UV spectrophotometric methods have been developed, simultaneous equation method, multicomponent analysis (II) and derivative spectroscopy method (III). The absorption maxima of the drugs were found to be 247, 259 and 272 nm, respectively for efavirenz, tenofovir disoproxil fumarate and lamivudine in methanol:water (50:50) solvent system. Efavirenz, tenofovir disoproxil fumarate and lamivu...
متن کامل