A Simulation Based Validation of a pTx Pulse Design Strategy Using Implant-Friendly Modes for Patients with DBS Implants

نویسندگان

  • Yigitcan Eryaman
  • Bastien Guerin
  • Can Akgun
  • Joaquin L. Herraiz
  • Adrian Martin
  • Angel Torrado-Carvajal
  • Norberto Malpica
  • Juan A. Hernandez
  • Emanuele Schiavi
  • Elfar Adalsteinsson
  • Lawrence L. Wald
چکیده

30 35 40 45 50 55 60 W/kg deg A Simulation Based Validation of a pTx Pulse Design Strategy Using Implant-Friendly Modes for Patients with DBS Implants Yigitcan Eryaman, Bastien Guerin, Can Akgun, Joaquin L. Herraiz, Adrian Martin, Angel Torrado-Carvajal, Norberto Malpica, Juan A. HernandezTamames, Emanuele Schiavi, Elfar Adalsteinsson, and Lawrence L. Wald Madrid-MIT M+Vision Consortium in RLE, MIT, Cambridge, Massachusetts, United States, Martinos Center for Biomedical Imaging, Dept. of Radiology, MGH, Charlestown, MA, United States, Invenshure, MN, United States, Dept. of Applied Mathematics, Rey Juan Carlos University, Madrid, Spain, Dept. of Electronic Technology, Rey Juan Carlos University, Madrid, Spain, Dept. of Electrical Engineering and Computer Science, MIT, Cambridge, Massachusetts, United States, Harvard-MIT Health Sciences and Technology, MIT, Cambridge, MA, United States

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging

Deep Brain Stimulation (DBS) is increasingly used to treat a variety of brain diseases by sending electrical impulses to deep brain nuclei through long, electrically conductive leads. Magnetic resonance imaging (MRI) of patients pre- and post-implantation is desirable to target and position the implant, to evaluate possible side-effects and to examine DBS patients who have other health conditio...

متن کامل

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

Effects of Triple Injection Strategies on Performance and Pollutant Emissions of a DI Diesel Engine Using CFD Simulation

One of the main controlling parameters in diesel engine combustion is the fuel – air mixing process that has direct effects on engine performance and pollutant emissions, reviewing over previous literature showed that split injection strategies could satisfy this purpose very well. For the first time and in this paper, pilot and double injection strategies were combined and formed new triple in...

متن کامل

Outcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial

Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013