30 35 40 45 50 55 60 W/kg deg A Simulation Based Validation of a pTx Pulse Design Strategy Using Implant-Friendly Modes for Patients with DBS Implants Yigitcan Eryaman, Bastien Guerin, Can Akgun, Joaquin L. Herraiz, Adrian Martin, Angel Torrado-Carvajal, Norberto Malpica, Juan A. HernandezTamames, Emanuele Schiavi, Elfar Adalsteinsson, and Lawrence L. Wald Madrid-MIT M+Vision Consortium in RLE, MIT, Cambridge, Massachusetts, United States, Martinos Center for Biomedical Imaging, Dept. of Radiology, MGH, Charlestown, MA, United States, Invenshure, MN, United States, Dept. of Applied Mathematics, Rey Juan Carlos University, Madrid, Spain, Dept. of Electronic Technology, Rey Juan Carlos University, Madrid, Spain, Dept. of Electrical Engineering and Computer Science, MIT, Cambridge, Massachusetts, United States, Harvard-MIT Health Sciences and Technology, MIT, Cambridge, MA, United States
منابع مشابه
Investigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging
Deep Brain Stimulation (DBS) is increasingly used to treat a variety of brain diseases by sending electrical impulses to deep brain nuclei through long, electrically conductive leads. Magnetic resonance imaging (MRI) of patients pre- and post-implantation is desirable to target and position the implant, to evaluate possible side-effects and to examine DBS patients who have other health conditio...
متن کاملFinite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کاملClinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading
Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...
متن کاملEffects of Triple Injection Strategies on Performance and Pollutant Emissions of a DI Diesel Engine Using CFD Simulation
One of the main controlling parameters in diesel engine combustion is the fuel – air mixing process that has direct effects on engine performance and pollutant emissions, reviewing over previous literature showed that split injection strategies could satisfy this purpose very well. For the first time and in this paper, pilot and double injection strategies were combined and formed new triple in...
متن کاملOutcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial
Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...