Clopidogrel in infants with systemic-to-pulmonary-artery shunts.

نویسندگان

  • David L Wessel
  • Felix Berger
  • Jennifer S Li
  • Ingo Dähnert
  • Amit Rakhit
  • Sylvie Fontecave
  • Jane W Newburger
چکیده

BACKGROUND Infants with cyanotic congenital heart disease palliated with placement of a systemic-to-pulmonary-artery shunt are at risk for shunt thrombosis and death. We investigated whether the addition of clopidogrel to conventional therapy reduces mortality from any cause and morbidity related to the shunt. METHODS In a multicenter, double-blind, event-driven trial, we randomly assigned infants 92 days of age or younger with cyanotic congenital heart disease and a systemic-to-pulmonary-artery shunt to receive clopidogrel at a dose of 0.2 mg per kilogram of body weight per day (467 infants) or placebo (439 infants), in addition to conventional therapy (including aspirin in 87.9% of infants). The primary efficacy end point was a composite of death or heart transplantation, shunt thrombosis, or performance of a cardiac procedure due to an event considered to be thrombotic in nature before 120 days of age. RESULTS The rate of the composite primary end point did not differ significantly between the clopidogrel group (19.1%) and the placebo group (20.5%) (absolute risk difference, 1.4 percentage points; relative risk reduction with clopidogrel, 11.1%; 95% confidence interval, -19.2 to 33.6; P=0.43), nor did the rates of the three components of the composite primary end point. There was no significant benefit of clopidogrel treatment in any subgroup, including subgroups defined by shunt type. Clopidogrel recipients and placebo recipients had similar rates of overall bleeding (18.8% and 20.2%, respectively) and severe bleeding (4.1% and 3.4%, respectively). CONCLUSIONS Clopidogrel therapy in infants with cyanotic congenital heart disease palliated with a systemic-to-pulmonary-artery shunt, most of whom received concomitant aspirin therapy, did not reduce either mortality from any cause or shunt-related morbidity. (Funded by Sanofi-Aventis and Bristol-Myers Squibb; ClinicalTrials.gov number, NCT00396877.).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical Closure of Left-to-Right Shunts in Premature Infants with Bronchopulmonary Dysplasia and Pulmonary Hypertension: A Cautionary Tale

Closure of a systemic to pulmonary shunt in premature infants with bronchopulmonary dysplasia may be beneficial, but in the presence of pulmonary hypertension is controversial. Here, we discuss two premature infants with pulmonary hypertension who developed acute pulmonary hypertensive crisis after closure of these shunts and hence advise caution.

متن کامل

Diagnostic Methods Congenital Heart Disease

Eleven patients with a total of 17 palliative systemic-pulmonary artery shunts underwent evaluation by electrocardiogram-gated magnetic resonance imaging (GMRI). GMRI successfully imaged 1 1 of 17 shunts (65%), including five of nine Blalock-Taussig shunts, four of six Glenn shunts, and both aortopulmonary shunts. All shunts except for the Waterston were imaged on coronal sections during end-sy...

متن کامل

Clinical outcomes of palliative surgery including a systemic-to-pulmonary artery shunt in infants with cyanotic congenital heart disease: does aspirin make a difference?

BACKGROUND Aspirin (ASA) often is used to prevent thrombosis in infants with congenital heart disease after placement of a systemic-to-pulmonary artery shunt, but its effect on outcomes is unknown. METHODS AND RESULTS The present multicenter study prospectively collected data on 1-year postoperative rates of death, shunt thrombosis, or hospitalization age <4 months for bidirectional Glenn/hem...

متن کامل

Lung mechanics in infants with left-to-right shunt congenital heart disease.

To clarify which hemodynamic measurement correlates best with lung mechanics in infants with congenital heart disease and left-to-right shunts, dynamic pulmonary function tests and echocardiography were performed in 26 infants with such disease (study infants) and in 37 normal, healthy infants (control infants). The tidal volume and pulmonary compliance (CL) were lower and airway resistance hig...

متن کامل

Balloon angioplasty for obstructed modified systemic-pulmonary artery shunts and pulmonary artery stenoses.

OBJECTIVES The results of percutaneous balloon angioplasty for obstructed modified Blalock-Taussig (BT) or central shunts and pulmonary artery (PA) stenoses were studied to assess its role as an alternative to second shunt and surgical PA angioplasty. BACKGROUND Obstruction of a modified shunt and PA stenosis related to the shunt or ductus are not infrequent. A second shunt with or without PA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The New England journal of medicine

دوره 368 25  شماره 

صفحات  -

تاریخ انتشار 2013