Renal function measurements from MR renography and a simplified multicompartmental model.

نویسندگان

  • Vivian S Lee
  • Henry Rusinek
  • Louisa Bokacheva
  • Ambrose J Huang
  • Niels Oesingmann
  • Qun Chen
  • Manmeen Kaur
  • Keyma Prince
  • Ting Song
  • Elissa L Kramer
  • Edward F Leonard
چکیده

The purpose of this study was to determine the accuracy and sources of error in estimating single-kidney glomerular filtration rate (GFR) derived from low-dose gadolinium-enhanced T1-weighted MR renography. To analyze imaging data, MR signal intensity curves were converted to concentration vs. time curves, and a three-compartment, six-parameter model of the vascular-nephron system was used to analyze measured aortic, cortical, and medullary enhancement curves. Reliability of the parameter estimates was evaluated by sensitivity analysis and by Monte Carlo analyses of model solutions to which random noise had been added. The dominant sensitivity of the medullary enhancement curve to GFR 1-4 min after tracer injection was supported by a low coefficient of variation in model-fit GFR values (4%) when measured data were subjected to 5% noise. These analyses also showed the minimal effects of bolus dispersion in the aorta on parameter reliability. Single-kidney GFR from MR renography analyzed by the three-compartment model (4.0-71.4 ml/min) agreed well with reference measurements from (99m)Tc-DTPA clearance and scintigraphy (r = 0.84, P < 0.001). Bland-Altman analysis showed an average difference of 11.9 ml/min (95% confidence interval = 5.8-17.9 ml/min) between model and reference values. We conclude that a nephron-based multicompartmental model can be used to derive clinically useful estimates of single-kidney GFR from low-dose MR renography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single Kidney GFR Measured using 3D MR Renography and a Multicompartmental Model

Synopsis A multicompartmental tracer kinetic model permits analysis of 3D MR renography data in terms of physiologic parameters such as glomerular filtration rate. Validation studies were performed in nine subjects, in whom single kidney GFR measurements were measured using radionuclide clearance methods. Agreement between model-fit values of SKGFR and reference values was high (r=0.77). Other ...

متن کامل

Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and Its Performance

Objective(s): Renography is used for the diagnostic evaluation of pediatric patients with a suspected obstruction of urinary tract or impaired renal function. The recommended dose for children have been released by the European Association of Nuclear Medicine, Society of Nuclear Medicine and Molecular Imaging, and Japanese Society of Nuclear Medicine. Since acquisition counts in dynamic scintig...

متن کامل

Comparison of two methods to determine single kidney GFR from MR renography: A multicompartmental model and Patlak- Rutland analysis

L. Bokacheva, A. Huang, H. Rusinek, M. Kaur, Q. Chen, E. Kramer, E. Leonard, V. S. Lee Department of Radiology, New York University School of Medicine, New York, New York, United States, Department of Chemical Engineering, Columbia University, New York, New York, United States Introduction Dynamic gadolinium-enhanced MR images of the kidneys have been investigated by several groups for the noni...

متن کامل

Dynamic three-dimensional MR renography for the measurement of single kidney function: initial experience.

A three-dimensional magnetic resonance (MR) renographic method to measure single kidney glomerular filtration rate (GFR) and split renal function was developed that is based on renal signal intensity measurements during 2-3 minutes after intravenous injection of a low dose (2 mL or 0.01 mmol/kg) of gadopentetate dimeglumine. In nine subjects, single kidney MR GFR indices correlated well with te...

متن کامل

Diuretic effect on the measurement of differential renal function using 99mTc-DMSA in patients with hydronephrosis [Persian]

Introduction: It has been suggested that calculation of differential renal function (DRF) using 99mTc-DMSA may lead to overestimation of the function of an obstructed kidney. The aim of this study was to evaluate the effect of diuretic administration on the determination of DRF using 99mTc-DMSA scintigraphy in patients with dilated pelvis. Methods: Thirty three patients, aged from 2 month...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Renal physiology

دوره 292 5  شماره 

صفحات  -

تاریخ انتشار 2007