Pattern-based sensing of nucleotides in aqueous solution with a multicomponent indicator displacement assay.
نویسندگان
چکیده
A multicomponent indicator displacement assay (MIDA) based on an organometallic receptor and three dyes can be used for the identification and quantification of nucleotides in aqueous solution at neutral pH.
منابع مشابه
Carbohydrate sensing with a metal-based indicator displacement assay.
A Pd-based indicator displacement assay for the fluorimetric sensing of carbohydrates has been developed. The assay allows the detection of saccharides in the low millimolar concentration range in water at neutral pH.
متن کاملSelective recognition of pyrophosphate in water using a backbone modified cyclic peptide receptor.
A cyclic peptide based receptor, bearing two dipicolylamino arms complexed to zinc(II) ions, binds pyrophosphate ions with high affinity and selectivity in aqueous solution as determined using an indicator displacement assay.
متن کاملSensing of biologically relevant d-metal ions using a Eu(III)-cyclen based luminescent displacement assay in aqueous pH 7.4 buffered solution.
1·Eu·BPS was developed as a luminescent lanthanide sensor for use in displacement assays for detection of d-metal ions by monitoring the changes in the europium emission, which was quenched for iron(II), with a detection limit of ∼10 pM (0.002 μg L(-1)) for Fe(II) in buffered pH 7.4 solution.
متن کاملA Lanthanide-Based Chemosensor for Bioavailable Fe3+ Using a Fluorescent Siderophore: An Assay Displacement Approach
The measurement of trace analytes in aqueous systems has become increasingly important for understanding ocean primary productivity. In oceanography, iron (Fe) is a key element in regulating ocean productivity, microplankton assemblages and has been identified as a causative element in the development of some harmful algal blooms. The chemosenor developed in this study is based on an indicator ...
متن کاملTiO2 based surface acoustic wave gas sensor with modified electrode dimensions for enhanced H2 sensing application
The design and optimization of nanostructure-based surface acoustic wave (SAW) gas sensor is analyzed based on TiO2 sensing layer and modified electrode dimensions. The sensitivity of the gas sensor depends upon the type of sensing layer used and active surface area obtained by varying the aspect ratio. The performance of the sensor is observed from 0.1ppm to 100ppm concentration of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chemical communications
دوره 23 شماره
صفحات -
تاریخ انتشار 2007