Damage to the cuff of EMG tube at endotracheal intubation by using a lightwand -A case report-

نویسندگان

  • Hyun-Sook Kim
  • Keun-Suk Park
  • Mae-Hwa Kang
  • Chong Doo Park
چکیده

Electromyogpraphic endotracheal tube (EMG tube) is a new device used to monitor recurrent laryngeal nerve integrity during thyroid surgery. The EMG tube has 2 pairs of electrodes on the surface of silicon-based tube reached to inner space of tube cuff. We experienced an unusual endotracheal tube-related problem from the distinct structural feature of the EMG tube. In this case, we intubated a patient who had difficult airway with the EMG tube using a lightwand. After successful endotracheal intubation, we could not expand the pilot balloon and ventilate the patient effectively. We removed the EMG tube and found that one of electrodes of the EMG tube is bended and made a right angle with the long axis of the tube, and perforated the tube cuff. So we report this case to make anesthesia providers aware that much more attention is needed to use EMG tube during endotracheal intubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeated Tracheostomy Tube Cuff Rupture Due to Tracheobronchopathia Osteochondroplastica: A Case Report

Introduction: Tracheobronchopathia osteochondroplastica (TPO) is a rare benign disorder of the lower part of the trachea and the upper part of the main bronchi.   Case Report: A case of tracheobronchopathia osteochondroplastica (TPO) diagnosed at the time of intubation in an intensive care unit due to difficulty when advancing the endotracheal tube beyond the vocal cords, is reported. A problem...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Study of endotracheal tube cuff pressure and time of measurement among intensive care units patients

Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...

متن کامل

بررسی و مقایسه تاثیر تزریق وریدی و داخل کاف هیدروکورتیزون بر فروانی و شدت سرفه بدنبال استفاده از لوله تراشه در بیهوشی اعمال جراحی باز شکستگی های اندام انتهایی

Abstract Introduction: Cough is a common complication after anesthesia can lead to serious complications. This study carried out to evaluate the effect of intravenous and intra-cuff hydrocortisone on the severity of cough after anesthesia using endotracheal tube. Methods: In this RCT study, 135 patients with distal limb were selected and randomly assigned in A, B and C group. After intuba...

متن کامل

Effect of Positioning on the Pressure of Endotracheal Tube Cuff Filled with Air versus Saline: A Double-blind Randomized Clinical Trial

Background: Control and maintenance of endotracheal tube cuff pressure and prevention of sore throat are major concerns in post-anesthesia care. Aim: This study aimed to evaluate changes in the pressure of the endotracheal tube cuff filled with saline versus air and post-anesthesia sore throat when the position is altered from supine to lateral. <st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 59  شماره 

صفحات  -

تاریخ انتشار 2010