Michelson interferometer with diffractively-coupled arm resonators in second-order Littrow configuration.
نویسندگان
چکیده
Michelson-type laser-interferometric gravitational-wave (GW) observatories employ very high light powers as well as transmissively-coupled Fabry-Perot arm resonators in order to realize high measurement sensitivities. Due to the absorption in the transmissive optics, high powers lead to thermal lensing and hence to thermal distortions of the laser beam profile, which sets a limit on the maximal light power employable in GW observatories. Here, we propose and realize a Michelson-type laser interferometer with arm resonators whose coupling components are all-reflective second-order Littrow gratings. In principle such gratings allow high finesse values of the resonators but avoid bulk transmission of the laser light and thus the corresponding thermal beam distortion. The gratings used have three diffraction orders, which leads to the creation of a second signal port. We theoretically analyze the signal response of the proposed topology and show that it is equivalent to a conventional Michelson-type interferometer. In our proof-of-principle experiment we generated phase-modulation signals inside the arm resonators and detected them simultaneously at the two signal ports. The sum signal was shown to be equivalent to a single-output-port Michelson interferometer with transmissively-coupled arm cavities, taking into account optical loss. The proposed and demonstrated topology is a possible approach for future all-reflective GW observatory designs.
منابع مشابه
Diffractively coupled Fabry-Perot resonator with power-recycling.
We demonstrate the optical coupling of two cavities without light transmission through a substrate. As the all-reflective coupling component, we use a dielectric low-efficiency 3-port diffraction grating. In contrast to a conventional transmissive coupling component, such an all-reflective coupler avoids all thermal effects that are associated with light absorption in the substrate. An all-refl...
متن کاملElectrically switchable cylindrical Fresnel lens based on holographic polymer-dispersed liquid crystals using a Michelson interferometer
Fabricating an electrically switchable cylindrical Fresnel lens based on holographic polymer-dispersed liquid crystals (H-PDLC) using a Michelson interferometer is reported. Simplicity of the method and possibility of fabricating different focal length lenses in a single set up are among the advantages of the method. It is demonstrated that the Fresnel structured zone plate acts as a cylindrica...
متن کاملAll-reflective Michelson, Sagnac, and Fabry-Perot interferometers based on grating beam splitters.
All-reflective Michelson, Sagnac, and Fabry-Perot interferometers based on grating beam splitters are experimentally demonstrated at a wavelength of 1064 nm. A 1200-groove/mm grating diffracting 0 and -1 orders with an efficiency of 48.2% for each order was used as a near-50/50 beam splitter. The all-reflective Sagnac and Michelson interferometers were formed by reintroducing both of the diffra...
متن کاملUse of Sagnac in Michelson Interferometer for Vortex Array Generation
A new configuration for optical vortex interferometer (OVI) is presented. The OVI makes use of dual arm interferometric architecture in which one of the arms contains a Sagnac interferometer. The vortex lattice is generated using superposition of three plane waves or spherical waves of same curvature.
متن کاملNonlinearity in a fiber-optic coupled heterodyne interferometer
A high-accuracy (nonlinearity < 2nm) fiber-optic coupled displacement heterodyne measuring Michelson interferometer is developed. The primary limitation of accuracy encountered with this fiber-optic coupled heterodyne interferometer is the optical mixing arising from the imperfection of fiber-optic coupling system. The optical mixing results in the nonlinearity (first order and second order err...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 20 23 شماره
صفحات -
تاریخ انتشار 2012