چکیده

BACKGROUND Microelectrode array (MEA) devices are frequently used in neural circuit studies, especially in retinal prosthesis. For a high throughput stimulation and recording paradigm, it is desirable to obtain the responses of multiple surface RGCs initiated from the electrical signals delivered to multiple photoreceptor cells. This can be achieved by an high density MEA-tissue-MEA (MTM) sandwich configuration. However, the retina is one of the most metabolically active tissues, consumes oxygen as rapidly as the brain. The major concern of the MTM configuration is the supply of oxygen. METHODS We aimed to develop a high density MTM sandwich platform which consists of stacks of a stimulation MEA, retinal tissue and a recording MEA. Retina is a metabolically active tissue and the firing rate is very sensitive to oxygen level. We designed, simulated and microfabricated porous high density MEAs and an adjustable perfusion system that electrical signals can be delivered to and recorded from the clipped retinal tissue. RESULTS The porous high-density MEAs linked with stimulation or recording devices within a perfusion system were manufactured and the MTM platform was assembled with a retina slice inside. The firing rate remained constant between 25 and 55 min before dramatically declined, indicating that within certain period of time (e.g. 30 min after habituation), the retina condition was kept by sufficient oxygen supply via the perfusion holes in the MEAs provided by the double perfusion system. CONCLUSIONS MTM sandwich structure is an efficient platform to study the retinal neural circuit. The material and arrangement of high density microelectrodes with porous design make this MEA appropriate for sub-retina prosthesis. Finding ways to prolong the recording time and reduce the signal-to-noise ratio are important to improve our MTM prototype.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Printed circuit microelectrodes and their application to honeybee brain.

The application of printed circuit technology to the production of a new type of multi-channel microelectrode is described. 2. Recordings have been obtained from the the protocerebrum of the honeybee Apis mellifera L. using printed circuit microelectrodes in both restrained and free-moving preparations. 3. These recordings are compared with those previously obtained from conventional probe micr...

متن کامل

Acute microelectrode array implantation into human neocortex: preliminary technique and histological considerations.

OBJECT Researchers at The Center for Neural Interfaces at the University of Utah have designed and produced a silicon-based high-density microelectrode array that has been used successfully in mammalian models. The authors investigate the ability to transfer array insertion techniques to humans and examine the acute response of human cortical tissue to array implantation. METHODS Six patients...

متن کامل

Recent Trends in Microelectrode Array Technology for In Vitro Neural Interface Platform

Microelectrode array (MEA) technology is a widely used platform for the study of in vitro neural networks as it can either record or stimulate neurons by accessing multiple sites of neural circuits simultaneously. Unlike intracellular recording techniques, MEAs form noninvasive interface with cells so that they provides relatively long time window for studying neural circuits. As the technology...

متن کامل

Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays.

Implantable silicon microelectrode array technology is a useful technique for obtaining high-density, high-spatial resolution sampling of neuronal activity within the brain and holds promise for a wide range of neuroprosthetic applications. One of the limitations of the current technology is inconsistent performance in long-term applications. Although the brain tissue response is believed to be...

متن کامل

Cortical signal recording using an economical microelectrode fabricated on printed circuit board

This work presents a simple, flexible and economical microwire array electrode for extracellular cortical recordings. The proposed procedure is relatively simple, even for a novice worker to implement in-house. These main steps include design and sculpturing PCB, straightening microwires, connecting PCB pattern, arraying and soldering microwires and packaging the microelectrode. A practiced res...