Effects of left ventricular assist device therapy on ventricular arrhythmias.
نویسندگان
چکیده
OBJECTIVES In a retrospective study, we sought to evaluate the effect of left ventricular assist device (LVAD) therapy on ventricular tachyarrhythmias in patients with advanced congestive heart failure. BACKGROUND Despite the increasing use of LVAD as a bridge to cardiac transplantation, our knowledge regarding its effect on ventricular arrhythmias is currently limited to small series. Little is known about the prevalence, predictors, and clinical consequences of ventricular arrhythmias in LVAD recipients. METHODS We reviewed the pre- and post-LVAD course of the last 100 consecutive adult patients to receive a HeartMate LVAD (Thoratec Laboratories Corp., Pleasanton, California) at our institution. All ventricular arrhythmias sustained for at least 30 s or requiring defibrillation were analyzed. All documented pre- and post-LVAD sustained ventricular arrhythmias were classified either as monomorphic ventricular tachycardia (MVT) or polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF). RESULTS Our population had an average age of 51 years, had predominately ischemic cardiomyopathy (63%), and a mean left ventricular ejection fraction of 20 +/- 10%. New-onset MVT was observed in 18 patients who did not have MVT before LVAD placement. After LVAD, new-onset MVT was 4.5 times more likely than elimination of previously present MVT (p = 0.001), whereas the effect of LVAD on incidence of PVT/VF was not significant. In a multivariate Cox proportional hazards regression analysis, serum electrolyte abnormality was an independent predictor of post-LVAD ventricular arrhythmias. Preoperative MVT did not predict postoperative MVT. CONCLUSIONS After LVAD placement, there is a significant rise in the incidence of de novo MVT. By contrast, the incidence of PVT/VF was unaffected by LVAD placement.
منابع مشابه
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملEffects of pretreatment with non hypotensive dose of ramiprilat and losartan on myocardial ischemia-reperfusion induced arrhythmias and infarct size in rats
Introduction: Inhibition of renin angiotensin system represents an important approach in the management of cardiovascular diseases. The aim of this study was to explore the effects of pretreatment with non-hypotensive dose of angiotensin converting enzyme (ACE) inhibitor, ramiprilat and angiotensin type 1 (AT1) receptor blocker, losartan on myocardial infarct size and arrhythmias in a rat mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 45 9 شماره
صفحات -
تاریخ انتشار 2005