Efficiency of a tool-mounted local exhaust ventilation system for controlling dust exposure during metal grinding operations.

نویسنده

  • Jun Ojima
چکیده

In general, control of metal dust from hand-held disk grinders is difficult because such respirable dust tends to disperse in every direction around the grinding wheel and cannot be captured effectively by a conventional exhaust hood. The author described the application of a custom-made tool-mounted local exhaust ventilation (LEV) system attached to a hand-held disk grinder, and by laboratory experiments assessed its effectiveness at dust control. The effectiveness of the LEV for dust control was assessed by determining the respirable dust concentration around the grinding wheel during metal surface grinding with and without the use of the LEV. It was shown that the average respirable grinding dust concentration decreased from 7.73 mg/m(3) with the LEV off to 4.87 mg/m(3) with the LEV on, a mean dust generation reduction of about 37%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The efficacy of local exhaust ventilation for controlling dust exposures during concrete surface grinding.

This study assessed the effectiveness of a commercially available local exhaust ventilation (LEV) system for controlling respirable dust and crystalline silica exposures during concrete grinding activities. Surface grinding was conducted at six commercial building construction sites in Seattle, WA, by cement masons. Time-integrated filter samples and direct reading respirable dust concentration...

متن کامل

کنترل غبار منتشره با تلفیق تهویه صنعتی و مه پاش به‌عنوان راهکار مؤثر و اقتصادی در یک شرکت معدنی

Background and aims: Dust emission is one of the main health and environmental problems during the crushing, screening and conveying process in mining company. The goal of this study was designing, implementation and evaluation of industrial ventilation and combination with a water spray for control the airborne particles as well as economic analysis on crushing unit of a mining compa...

متن کامل

The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities.

This study assessed the effectiveness of commercially available local exhaust ventilation (LEV) systems for controlling respirable dust and crystalline silica exposures during concrete cutting and grinding activities. Work activities were performed by union-sponsored apprentices and included tuck-point grinding, surface grinding, paver block and brick cutting (masonry saw), and concrete block c...

متن کامل

Efficiency of Dust Capture from Metal Grinding

According to the Machinery Directive 2006/42/EC, one of the essential requirements relating to occupational safety and health hazards is to prevent dust pollution emitted by machinery during the implementation processes. Research on evaluation of emissions from machinery, according to the method of test bench using tracer gases, are currently being conducted in CIOP-PIB. This article presents s...

متن کامل

طراحی، اجرا و ارزیابی سیستم تهویه صنعتی و غبار گیرهای واحد خردایش یک شرکت تولیدی کربورسیلیسیوم

Background & objective: Industrial ventilation systems and dust collectors are effective solutions to reduce particulate emissions in the workplace and environmental in mineral processes. In this study, Local Exhaust Ventilation System and dust collectors for control of emitted silica, coke, silicon carbide dusts from crushing unit was designed and evaluated. Methods: : Local Exhaust venti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial health

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 2007