Documentation of specific mesh implant at the time of midurethral sling surgery in women with stress incontinence.

نویسندگان

  • Nadine C Kassis
  • Jennifer C Thompson
  • Anne M Scheidler
  • Joanne K Daggy
  • Douglass S Hale
چکیده

OBJECTIVE We aimed to assess documentation completeness of the operative record for mesh implanted at the time of midurethral sling surgery and to identify modifiable predictors of documentation completeness. METHODS A retrospective cross-sectional study of women with stress incontinence who underwent midurethral sling placement between January 2009 and December 2011 was conducted. Data from the dictated operative note and nursing operative record were extracted to determine if the specific mesh implanted during surgery was documented. The primary outcome was the rate of documentation of mesh implanted in the physician's dictated operative note and in the nursing record. Logistic regression was used to determine if any characteristics were associated with the rate of documentation while accounting for correlation of patients from the same dictating surgeon. RESULTS There were 816 surgeries involving the implantation of a midurethral sling during the study period. All surgeries were performed at 6 Indiana University hospitals. Fifty-two surgeons of varying specialties and levels of training dictated the operative notes. A urogynecologist dictated 71% of the operative notes. The rate of documentation completeness for mesh implanted in the physician's note was 10%. The rate of documentation completeness for mesh implanted in the nursing operative record was 92%. Documentation of mesh implanted in the physician's note was not significantly associated with the level of training, specialty, or year of surgery. CONCLUSIONS Documentation completeness for specific mesh implant in the physician's note is low, independent of specialty and level of training. Nursing documentation practices are more rigorous. Postmarket surveillance, currently mandated by the Food and Drug Administration, may not be feasible if only the physician's note is available or if nursing practices are inconsistent. Development of documentation guidelines for physicians would improve the feasibility of surveillance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does a midurethral sling inserted at the time of pelvic organ prolapse mesh surgery increase the rate of de novo OAB? A prospective longitudinal study.

OBJECTIVES Approximately 20% of women suffer from pelvic organ prolapse (POP) and stress urinary incontinence (SUI). Furthermore, POP and overactive bladder (OAB) symptoms often coexist. Midurethral slings and mesh surgeries are both considered to be risk factors for de novo OAB symptoms. The aim of our study was to determine whether simultaneous midurethral sling insertion at the time of pelvi...

متن کامل

Is there an association between polypropylene midurethral slings and malignancy?

OBJECTIVE To examine any association between polypropylene mesh used in midurethral slings and malignancy in humans. Macroporous, monofilament polypropylene midurethral slings have been established as a safe and effective treatment for stress urinary incontinence. However, despite long-term studies supporting the efficacy and safety of midurethral slings, there have been concerns regarding the ...

متن کامل

The clinical effectiveness of transobturator midurethral sling (T-sling) with additional 2-point tape fixation performed on inpatient and outpatient basis

Nowadays midurethral sling are considered as a gold standard for stress urinary incontinence [1][Fig.1]. Traditionally, this technique has been followed by hospitalization and short inpatient convalescence. From both patient and physician perspective, this technique became increasingly popular due to very high clinical effectiveness, fast recovery, no need of painful incisions or overnight hosp...

متن کامل

Surgical intervention for stress urinary incontinence: comparison of midurethral sling procedures.

CONTEXT The synthetic, tension-free midurethral sling was introduced in the 1990s as a surgical treatment for women with stress urinary incontinence (SUI). Several similar products are now available. The authors generated data comparing clinical outcomes of two midurethral sling procedures. OBJECTIVE To compare clinical outcomes of two midurethral sling procedures currently used for the treat...

متن کامل

Contemporary comparison between retropubic midurethral sling and autologous pubovaginal sling for stress urinary incontinence after the FDA advisory notification.

OBJECTIVE To compare the efficacy and safety in a contemporary cohort of women who were offered either a pubovaginal sling (PVS) or a synthetic midurethral sling (MUS) after the U.S. Food and Drug Administration notification and made an informed decision on procedure option. METHODS A total of 201 women were given the option between a PVS and an MUS. Prior anti-incontinence surgery and concom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Female pelvic medicine & reconstructive surgery

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2015