Evaluation of commercially available electrodes and gels for recording of slow EEG potentials.
نویسندگان
چکیده
OBJECTIVE To test the applicability of different types of commercially available electrodes and electrode gels or pastes for recording of slow EEG potentials. METHODS Experiments were carried out on six types of reusable electrodes (silver, tin and gold cup electrodes, sintered silver-silver chloride (Ag|AgCl), platinum, stainless steel), six disposable Ag|AgCl electrode models, and nine gels or pastes. We studied the parameters, which are critical in slow-potential recording, such as polarization, initial and long-term stability and low-frequency noise. RESULTS The best results were obtained with the reusable sintered Ag|AgCl electrodes. The six disposable Ag|AgCl electrode models also proved to have appropriate electrical properties. Other types of reusable electrodes suffered from diverse degrees of polarization, baseline drift, low-frequency noise, high resistance, and changes in properties due to wear and tear. Seven out of nine gels or pastes contained a significant amount of chloride, which is a prerequisite for DC stability of Ag|AgCl electrodes, whereas the absolute concentration of chloride had little effect. CONCLUSIONS Direct current (DC) coupled recording of EEG is critically dependent on the choice of electrode and gel. SIGNIFICANCE Our results provide rigorous criteria for choosing DC-stable electrodes and gels for DC-coupled or long time-constant AC-coupled recordings of slow EEG potentials.
منابع مشابه
A dry electrode for EEG recording.
This paper describes the design, fabrication and testing of a prototype dry surface electrode for EEG signal recording. The new dry electrode has the advantages of no need for skin preparation or conductive paste, potential for reduced sensitivity to motion artifacts and an enhanced signal-to-noise ratio. The electrode's sensing element is a 3 mm stainless steel disk which has a 2000 A (200 nm)...
متن کاملAn EEG system with carbon wire electrodes and an anti-polarization circuit for simultaneous EEG-fMRI recording
Background Simultaneous EEG-fMRI (Electroencephalography-functional Magnetic Resonance Imaging) recording offers high temporal resolution electrophysiological recording and high spatial resolution hemodynamic recording from the same experimental runs. Carbon wire electrodes (but not solid electrodes with carbon leads) are suitable for simultaneous EEG-fMRI recording, especially in high field MR...
متن کاملEvaluation of a Low-cost and Low-noise Active Dry Electrode for Long-term Biopotential Recording
Wet Ag/AgCl electrodes, although very popular in clinical diagnosis, are not appropriate for expanding applications of wearable biopotential recording systems which are used repetitively and for a long time. Here, the development of a low-cost and low-noise active dry electrode is presented. The performance of the new electrodes was assessed for recording electrocardiogram (ECG) and electroence...
متن کاملDC-EEG recording: a paradigm shift in seizure localization?
Interictal or ictal discharges are the basis of EEG interpretation when seizure localization is the goal, but a new report suggests an alternative. It has been known for over 40 years that, when DC recordings are made, seizures may be associated with localized, very slow, sustained voltage changes, which do not oscillate (ictal DC shift).1 These voltage changes occur more or less simultaneously...
متن کاملTechnical and clinical analysis of microEEG: a miniature wireless EEG device designed to record high-quality EEG in the emergency department
UNLABELLED BACKGROUND We describe and characterize the performance of microEEG compared to that of a commercially available and widely used clinical EEG machine. microEEG is a portable, battery-operated, wireless EEG device, developed by Bio-Signal Group to overcome the obstacles to routine use of EEG in emergency departments (EDs). METHODS The microEEG was used to obtain EEGs from healthy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
دوره 116 4 شماره
صفحات -
تاریخ انتشار 2005