Cosmic muon tomography of pure cesium iodide calorimeter crystals
نویسندگان
چکیده
Scintillation properties of pure CsI crystals used in the shower calorimeter being built for precise determination of the π→πeνe decay rate are reported. Seventyfour individual crystals, polished and wrapped in Teflon foil, were examined in a multiwire drift chamber system specially designed for transmission cosmic muon tomography. Critical elements of the apparatus and reconstruction algorithms enabling measurement of spatial detector optical nonuniformities are described. Results are compared with a Monte Carlo simulation of the light response of an ideal detector. The deduced optical nonuniformity contributions to the FWHM energy resolution of the PIBETA CsI calorimeter for the π+→e+ν 69.8MeV positrons and the monoenergetic 70.8MeV photons were 2.7% and 3.7%, respectively. The upper limit of optical nonuniformity correction to the 69.8MeV positron low-energy tail between 5MeV and 55MeV was +0.2%, as opposed to the +0.3% tail contribution for the photon of the equivalent total energy. Imposing the 5 MeV calorimeter veto cut to suppress the electromagnetic losses, GEANT-evaluated positron and photon lineshape tail fractions summed over all above-threshold ADCs were found to be 2.36± 0.05(stat)± 0.20(sys)% and 4.68± 0.07(stat)± 0.20(sys)%, respectively. Preprint submitted to Elsevier Preprint 7 February 2008 PACS Numbers: 87.59.F; 29.40.Mc; 24.10.Lx
منابع مشابه
رشد تک بلور هالید قلیایی یدید سزیم در کوره پنج منطقهای با روش بریجمن
In this research, the vertical Bridgman method has used to perform the single crystal growth of cesium iodide alkali halide. To this purpose, a vertical cylindrical furnace equipped with electric elements with five different thermal regions has been designed and constructed. The temperature gradient of the furnace can be controlled up to 1000○C with 0.1○C accuracy. Several cesium iodide sample ...
متن کاملLight response of pure CsI calorimeter crystals painted with wavelength - shifting lacquer
We have measured scintillation properties of pure CsI crystals used in the shower calorimeter built for a precise determination of the π→πeνe decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals painted with a special wavelength-shifting solution were examined in a custom-build detection apparatus (RASTA—radioactive source tomography apparatus) that uses a 137Cs radioact...
متن کاملDevelopment of crystals based on cesium iodide for measurements of gamma radiation and alpha particles*
In recent years, the search for new scintillators has renewed, increasing the needs for the development of high-energy physics, nuclear tomography and other fields of science and engineering. For high energy particle accelerators, it is common the use of multiple detectors capable of working under high counting rates, requiring detectors with short decay time (about 10 ns) and high density [3, ...
متن کاملWater-equivalent path length calibration of a prototype proton CT scanner.
PURPOSE The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. METHODS A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the...
متن کاملA ROOT Tool for 3D Event Visualization in ATLAS Calorimeter
The ATLAS (A Toroidal LHC ApparatuS) detector is being tested with cosmic rays before LHC (Large Hadron Collider) starts its full operation by the midle of the year 2008. For the ongoing commissioning phase, it is necessary to develop specific tools that can perform efficient cosmic ray data analysis. An important issue for final analysis is to provide a way to visualize cosmic muon tracks and ...
متن کامل