BACKGROUND To assess the benefits of bladder wall sub-volume equivalent uniform dose (EUD) constraints in prostate cancer intensity-modulated radiotherapy (IMRT) planning. METHODS Two IMRT plans, with and without EUD constraints on the bladder wall, were generated using beams that deliver 80 Gy to the prostate and 46 Gy to the seminal vesicles and were compared in 53 prostate cancer patients. The bladder wall was defined as the volume between the external manually delineated wall and a contraction of 7 mm apart from it. The bladder wall was then separated into two parts: the internal-bladder wall (bla-in) represented by the portion of the bladder wall that intersected with the planning target volume (PTV) plus 5 mm extension; the external-bladder wall (bla-ex) represented by the remaining part of the bladder wall. In the IMRT plan with EUD constraints, the values of "a" parameter for the EUD models were 10.0 for bla-in and 2.3 for bla-ex. The plans with and without EUD constraints were compared in terms of dose-volume histograms, 5-year bladder and rectum normal tissue complication probability values, as well as tumor control probability (TCP) values. RESULTS The use of bladder sub-volume EUD constraints decreased both the doses to the bladder wall (V70: 22.76% vs 19.65%, Dmean: 39.82 Gy vs 35.45 Gy) and the 5-year bladder complication probabilities (≥LENT/SOMA Grade 2: 20.35% vs 17.96%; bladder bleeding: 10.63% vs 8.64%). The doses to the rectum wall and the rectum complication probabilities were also slightly decreased by the EUD constraints compared to physical constraints only. The minimal dose and the V76Gy of PTVprostate were, however, slightly decreased by EUD optimization, nevertheless without significant difference in TCP values between the two plans, and the PTV parameters finally respected the Groupe d'Etude des Tumeurs Uro-Génitales recommendations. CONCLUSION Separating the bladder wall into two parts with appropriate EUD optimization may reduce bladder toxicity in prostate IMRT. Combining biological constraints with physical constraints in the organs at risk at the inverse planning step of IMRT may improve the dose distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Step-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer

Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...

متن کامل

The Relationship between the Different Prostate Intensity Modulated Radiation Therapy Techniques and Patient’s Anatomical Parameters

Introduction: Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Different IMRT methods can apply for irradiating the prostate, but there is not clear that which of these methods can provide better dose distribution for each patient individually. Therefore, the aim of this study was to evaluate the relationship between the different prosta...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2016