Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease

نویسندگان

  • Kolja M. Thierfelder
  • Georgios Meimarakis
  • Konstantin Nikolaou
  • Wieland H. Sommer
  • Peter Schmitt
  • Philipp M. Kazmierczak
  • Maximilian F. Reiser
  • Daniel Theisen
چکیده

PURPOSE The aim of this study was to assess the diagnostic performance of ECG-gated non-contrast-enhanced quiescent interval single-shot (QISS) magnetic resonance angiography at a magnetic field strength of 3 Tesla in patients with advanced peripheral arterial occlusive disease (PAOD). METHOD AND MATERIALS A total of 21 consecutive patients with advanced PAOD (Fontaine stage IIb and higher) referred for peripheral magnetic resonance angiography (MRA) were included. Imaging was performed on a 3 T whole body MR. Image quality and stenosis diameter were evaluated in comparison to contrast-enhanced continuous table and TWIST MRA (CE-MRA) as standard of reference. QISS images were acquired with a thickness of 1.5 mm each (high-resolution QISS, HR-QISS). Two blinded readers rated the image quality and the degree of stenosis for both HR-QISS and CE-MRA in 26 predefined arterial vessel segments on 5-point Likert scales. RESULTS With CE-MRA as the reference standard, HR-QISS showed high sensitivity (94.1%), specificity (97.8%), positive (95.1%), and negative predictive value (97.2%) for the detection of significant (≥ 50%) stenosis. Interreader agreement for stenosis assessment of both HR-QISS and CE-MRA was excellent (κ-values of 0.951 and 0.962, respectively). As compared to CR-MRA, image quality of HR-QISS was significantly lower for the distal aorta, the femoral and iliac arteries (each with p<0.01), while no significant difference was found in the popliteal (p = 0.09) and lower leg arteries (p = 0.78). CONCLUSION Non-enhanced ECG-gated HR-QISS performs very well in subjects with severe PAOD and is a good alternative for patients with a high risk of nephrogenic systemic fibrosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High acceleration quiescent-interval single shot magnetic resonance angiography at 3T in patients with peripheral artery disease

Background Quiescent-Interval Single Shot (QISS) non-contrast MR angiography (QISS-MRA) is an emerging technique with growing evidence for its use in the evaluation of peripheral artery disease (PAD) at 1.5T [1,2]. The use of 3 Tesla MRI scans is becoming more common in clinical practice and offers the main advantage of roughly double the signal-to-noise ratio (SNR) than that of 1.5 Tesla MRI. ...

متن کامل

Intraarterial contrast-enhanced MR aortography with and without parallel acquisition technique in patients with peripheral arterial occlusive disease.

OBJECTIVE Repeated intraarterial gadolinium injections are necessary in endovascular MRI-guided interventions; therefore a low-dose protocol with a short acquisition time is preferable. The purpose of this study was to conduct a quantitative comparison of intraarterial MR aortograms obtained with and without high-speed parallel acquisition technique. SUBJECTS AND METHODS Intraarterial MR aort...

متن کامل

SNR Optimized Contrast-Enhanced MRA of the Peripheral Vasculature using Patient Specific Timing Parameters: Comparison between High and Conventional Relaxivity Contrast Agents in Patient Suspected of Arterial Occlusive Disease

Introduction Single injection moving table peripheral contrast enhanced MR angiography is increasingly utilized for the evaluation of peripheral atherosclerotic occlusive disease (PAOD). Peripheral MRA (pMRA) is typically performed using a moving table technique during first passage of double to triple dose (0.2-0.3 mmol/kg) extracellular gadolinium chelate. The objective of this study was to c...

متن کامل

Mapping of Autogenous Saphenous Veins as an Imaging Adjunct to Peripheral MR Angiography in Patients with Peripheral Arterial Occlusive Disease and Peripheral Bypass Grafting: Prospective Comparison with Ultrasound and Intraoperative Findings

BACKGROUND Mapping of the great saphenous vein is very important for planning of peripheral and coronary bypass surgery. This study investigated mapping of the great saphenous vein as an adjunct to peripheral MR angiography using a blood pool contrast agent in patients who were referred for evaluation of peripheral arterial occlusive disease and bypass surgery. METHODS 38 patients with periph...

متن کامل

3T versus 1.5T MR angiography in peripheral arterial occlusive disease: an equivalence trial in comparison with digital subtraction angiography

Background Contrast-enhanced MR angiography (CE-MRA) has evolved into a reliable imaging technique for peripheral arterial occlusive disease (PAOD). Recent advances in MRI technology offer large homogeneous magnetic fields with comparable Field-of-Views at 3T and 1.5T, allowing visualization of the complete runoff vascular tree by single-injection 3-station (pelvic/thigh/calf) moving-table CE-M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014