Multichannel radiometer calibration: a new approach.

نویسندگان

  • Susana Diaz
  • Charles R Booth
  • Roy Armstrong
  • Claudio Brunat
  • Sergio Cabrera
  • Carolina Camilion
  • Claudio Casiccia
  • Guillermo Deferrari
  • Humberto Fuenzalida
  • Charlotte Lovengreen
  • Alejandro Paladini
  • Jorge Pedroni
  • Alejandro Rosales
  • Horacio Zagarese
  • Maria Vernet
چکیده

The error in irradiance measured with Sun-calibrated multichannel radiometers may be large when the solar zenith angle (SZA) increases. This could be particularly detrimental in radiometers installed at mid and high latitudes, where SZAs at noon are larger than 50 degrees during part of the year. When a multiregressive methodology, including the total ozone column and SZA, was applied in the calculation of the calibration constant, an important improvement was observed. By combining two different equations, an improvement was obtained at almost all the SZAs in the calibration. An independent test that compared the irradiance of a multichannel instrument and a spectroradiometer installed in Ushuaia, Argentina, was used to confirm the results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrieval of Mixing Height by Multichannel Microwave Radiometer Observations

The mixing layer height (MLH) defines the top of the layer near the surface where turbulent mixing is occurring. In the recent years, new algorithms have been developed for estimating MLH, though the automatic detection of the top of the mixing layer still remains challenging. For example, when the MLH is estimated from lidar data, the lidar overlap limit may mask the early growth of the mixing...

متن کامل

Multichannel camera calibration

For the latest computer vision applications, it becomes more and more popular to take advantage of multichannel cameras (RGB cameras, etc.) to obtain not only gray values but also color information of pixels. The currently most common approach for multichannel camera calibration is the straightforward application of methods developed for calibration of single channel cameras. These conventional...

متن کامل

Analysis and improvement of tipping calibration for ground-based microwave radiometers

The tipping-curve calibration method has been an important calibration technique for ground-based microwave radiometers that measure atmospheric emission at low optical depth. The method calibrates a radiometer system using data taken by the radiometer at two or more viewing angles in the atmosphere. In this method, the relationship between atmospheric opacity and viewing angle is used as a con...

متن کامل

Multichannel Kondo approach to the cuprate and recent laser ARPES data

The existing theoretical approaches have been unable to confront the large corpus of outstanding data on the cuprate superconductor in a persuasive and unified manner. There is a general opinion now growing that these theories miss some essential points. We propose one based on multichannel Kondo effect that is physically justifiable and confronts the data adequately. In addition to earlier da...

متن کامل

PAU/RAD: Design and Preliminary Calibration Results of a New L-Band Pseudo-Correlation Radiometer Concept

The Passive Advanced Unit (PAU) for ocean monitoring is a new type of instrument that combines in a single receiver and without time multiplexing, a polarimetric pseudo-correlation microwave radiometer at L-band (PAU-RAD) and a GPS reflectometer (PAU-GNSS/R). These instruments in conjunction with an infra-red radiometer (PAU-IR) will respectively provide the sea surface temperature and the sea ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 44 26  شماره 

صفحات  -

تاریخ انتشار 2005