Hand-Eye Calibration of SCARA Robots
نویسندگان
چکیده
In SCARA robots, which are often used in industrial applications, all joint axes are parallel, covering three degrees of freedom in translation and one degree of freedom in rotation. Therefore, conventional approaches for the handeye calibration of articulated robots cannot be used for SCARA robots. In this paper, we present a new linear method that is based on dual quaternions and extends the work of [1] for SCARA robots. To improve the accuracy, a subsequent nonlinear optimization is proposed. We address several practical implementation issues and show the effectiveness of the method by evaluating it on synthetic and real data.
منابع مشابه
A minimal kinematic model for serial robot calibration using POE formula
Traditional methods based on the product of exponentials (POE) formula are parametrically continuous and complete for the calibration of the kinematic parameters of serial robots. However, these methods are not minimal due to the constraints of joint twists. This paper puts forward a new POE-based model, whose parameters are totally independent and conform to the formula of minimality. This is ...
متن کاملOn the dynamics of SCARA robot
Padhy, S.K., On the dynamics of SCARA robot, Robotics and Autonomous Systems, 10 (1992) 71-78. Assembly automation using robots has proven to be very successful. It has been shown that use of robots improves the accuracy of assembly, and saves assembly time and cost as well. SCARA (Selective Compliance Assembly Robot Arm) type robots have been widely used in industry for assembly operations in ...
متن کاملMotion Planning of SCARA Robots for Trajectory Tracking
The paper presents a method for a simple and immediate motion planning of a SCARA robot, whose end-effector has to move along a given trajectory; the calculation procedure requires the user to define in analytical form or by points the trajectory to be followed and to assign the curvilinear abscissa as function of the time. On the basis of the geometrical characteristics of the robot, a specifi...
متن کاملKinetostatic calibration of a SCARA robot
In this paper we propose a new algorithm for the kinetostatic calibration of a robot based on contact force measurement. The proposed calibration methodology, called kinetostatic calibration, does not require the use of a sensor to measure the robot pose, avoiding all problems related to the use of external devices for this measurement. On the contrary, the robot gripper must be equipped with a...
متن کاملDesign and Construction of a Manipulator Type Scara, Implementing a Control System
This paper describes the design and construction of a Robot manipulator type SCARA (Selective Compliance Assembly Robot Arm). The robots SCARA are robots of 3 degrees of freedom, uncounted the end off, designed for the assembling of pieces and the selective manipulation its control system, allows the positioning of the end effector in their points of work (control point to point PTP). For the d...
متن کامل