نویسندگان
چکیده
indicates the location of metal implants. b) Auto-calibrated SENSE (RMSE = 1037). c) SENSE with single calibration (RMSE = 3364). The arrow indicates image artifacts. d) Autocalibrated ARC (RMSE=372). e) ARC recon using single calibration (RMSE = 383). f) ARC recon using two concatenated calibration data sets (RMSE = 364). Figure 3: a) Fast spin-echo image. b) Fully sampled MAVRIC image c)Under-sampled MAVRIC image d) Autocalibrated ARC recon (RMSE = 504593). e) ARC recon using single calibration with zero resonance frequency offset data as calibration data (RMSE = 2687053). f) ARC recon using single calibration with two concatenated data as calibration data (RMSE = 1872306) Parallel MRI near metallic implants
منابع مشابه
Fat-Suppressed and Distortion-Corrected MRI Near Metallic Implants
Introduction: The use of orthopedic implants including joint replacements and fixation devices is increasingly common, necessitating follow-up evaluation to assess possible complications such as loosening or infection. Due to metal-induced distortion and other artifacts on conventional MRI, follow-up is often limited to Xray images. With additional encoding and parallel imaging, MR images with ...
متن کاملSEMAC: Slice Encoding for Metal Artifact Correction in MRI.
Magnetic resonance imaging (MRI) near metallic implants remains an unmet need because of severe artifacts, which mainly stem from large metal-induced field inhomogeneities. This work addresses MRI near metallic implants with an innovative imaging technique called "Slice Encoding for Metal Artifact Correction" (SEMAC). The SEMAC technique corrects metal artifacts via robust encoding of each exci...
متن کاملReal Time Measurement of Heating Near Metallic Implants Throughout a Phantom Using Phase-Shift MR Thermometry
H. Bassen, A. Kam, W. Kainz, G. Mendoza, H. Wang Center for Devices and Radiological Health, Food and Drug Administration, Rockville, MD, United States, Diagnostic Radiology Department, National Institutes of Health, Bethesda, MD, United States Introduction – Potentially dangerous heating occurs at the narrow tip of certain medical implants in patients being imaged by standard MRI systems [1, 2...
متن کاملHexagonal undersampling for faster MRI near metallic implants.
PURPOSE Slice encoding for metal artifact correction acquires a three-dimensional image of each excited slice with view-angle tilting to reduce slice and readout direction artifacts respectively, but requires additional imaging time. The purpose of this study was to provide a technique for faster imaging around metallic implants by undersampling k-space. METHODS Assuming that areas of slice d...
متن کاملAssessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips
PURPOSE Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. METHODS A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316L...