Quantitative T(1)(ρ) imaging using phase cycling for B0 and B1 field inhomogeneity compensation.
نویسندگان
چکیده
T(1)(ρ) imaging is useful in a number of clinical applications. T(1)(ρ) preparation methods, however, are sensitive to non-uniformities of the B0 magnetic field and the B1 RF field. These common system imperfections can result in image artifacts and quantification errors in T(1)(ρ) imaging. We report on a phase-cycling method which can eliminate B1 RF inhomogeneity effects in T(1)(ρ) imaging. This method does not only correct for image artifacts but also for T(2)(ρ) contamination caused by B1 RF inhomogeneity. The presence of B0 magnetic field inhomogeneity can compromise the effectiveness of this method for B1 RF inhomogeneity correction. We demonstrate that, by combining the spin-locking scheme reported by Dixon et al. (Myocardial suppression in vivo by spin locking with composite pulses. Magn Reson Med 1996; 36:90-94) with phase cycling, we can simultaneously correct B0 magnetic field inhomogeneity effects and B1 RF inhomogeneity effects in T(1)(ρ) imaging. Phantom and in vivo data sets are used to demonstrate the proposed methods and to compare them with other existing T(1)(ρ) preparation methods.
منابع مشابه
FIELD INHOMOGENEITY COMPENSATION IN HIGH FIELD MAGNETIC RESONANCE IMAGING (MRI) by
FIELD INHOMOGENEITY COMPENSATION IN HIGH FIELD MAGNETIC RESONANCE IMAGING (MRI) Zhenghui Zhang, PhD University of Pittsburgh, 2006 This thesis concentrates on the reduction of field (both main field B0 and RF field B1) inhomogeneity in MRI, especially at high B0 field. B0 and B1 field inhomogeneity are major hindrances in high B0 field MRI applications. B1 inhomogeneity will lead to spatially v...
متن کاملDTI at 7 and 3 T: systematic comparison of SNR and its influence on quantitative metrics.
Diffusion tensor imaging (DTI) and advanced related methods such as diffusion spectrum and kurtosis imaging are limited by low signal-to-noise ratio (SNR) at conventional field strengths. DTI at 7 T can provide increased SNR; however, B0 and B1 inhomogeneity and shorter T2⁎ still pose formidable challenges. The purpose of this study was to quantify and compare SNR at 7 and 3 T for different par...
متن کاملFour dimensional spectral-spatial fat saturation pulse design.
PURPOSE The conventional spectrally selective fat saturation pulse may perform poorly with inhomogeneous amplitude of static (polarizing) field (B0 ) and/or amplitude of (excitation) radiofrequency field (B1 ) fields. We propose a four dimensional spectral-spatial fat saturation pulse that is more robust to B0/B1 inhomogeneity and also shorter than the conventional fat saturation pulse. THEOR...
متن کاملA method for macroscopic B0 field inhomogeneity compensated SWI using 3D z-shim multi-echo GRE
Purpose Susceptibility weighted imaging (SWI) based on GRE provides enhancement of susceptibility difference which is useful for visualization of vein, micro-hemorrhage and iron deposition. However, GRE suffers from the macroscopic B0 inhomogeneity due to air/tissue boundary and this effect is shown as SNR loss both in magnitude and phase. Previously, 3D z-shim multi-echo GRE (mGRE) pulse seque...
متن کاملDispersion Relation for Alfvén Waves in a Viscous, Diffusive Plasma
Propagation of Alfvén waves in the solar plasma has been a topic of scientific interest for a long time. We have derived a dispersion relation ω4 + ω2[(ν2 + η2)k4 − v2 A k2] + iω(ν + η)v2 A k4 + (νηv2 A k6 + ν2η2k8) = 0 for shear Alfvén waves in a viscous and diffusive plasma. The MHD equations for viscous and diffusive plasma are ρ ∂ → v ∂t + ρ( → v .∇) →v= 1 μ (∇× → B)× → B +ρν∇ → v Momentum ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 29 5 شماره
صفحات -
تاریخ انتشار 2011