Pulse Shape Analysis of PD Signals – an efficient Tool to Monitor the Condition of Oils

نویسندگان

  • Rainer Patsch
  • Johannes Menzel
چکیده

Abstract: Partial discharges in oils are influenced by the actual dielectric properties of the liquid and especially degradation products may influence the phenomena. As a consequence of ageing processes in the liquid, oil molecules may be split into molecules of shorter lengths. The energy of a PD in the oil may heat the liquid locally and especially low molecular weight products in the oil will evaporate and form a gaseous phase within the liquid. This second phase can be generated in solids as well as in liquids. In solids the pressure in this gas phase will increase in accordance to the concentration of gas molecules. In liquids, an increase of the concentration of molecules will lead to an extension of the gas volume until the pressure within the void corresponds to the external gas pressure. Consequently, in accordance to Paschen’s law gas discharges may occur in this gas phase immediately (i.e. within μs) after a PD that generated the gas filled void. The sequence will be so quick that commonly used equipment may not be able to monitor these discharges separately. Analyses of the pulse shape of the PD signals after the band pass filter showed differences in accordance to the degree of ageing of the oils examined. Possibilities to use characteristic parameters of the pulse shape for diagnostic purposes and especially their correlation to other dielectric properties will be discussed in detail.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

Design and Performance Analysis of 7-Level Diode Clamped Multilevel Inverter Using Modified Space Vector Pulse Width Modulation Techniques

In this paper, a 7-level Diode Clamped Multilevel Inverter (DCMLI) is simulated with three different carrier PWM techniques. Here, Carrier based Sinusoidal Pulse Width Modulation (SPWM), Third Harmonic Injected Pulse Width Modulation (THIPWM) and Modified Carrier-Based Space Vector Pulse Width Modulation (SVPWM) are used as modulation strategies. These modulation strategies include Phase Dispos...

متن کامل

Evaluating the Improvement of Partial Discharge Localization Accuracy Using Frequency Response Assurance Criterion

Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...

متن کامل

Extending the Radar Dynamic Range using Adaptive Pulse Compression

The matched filter in the radar receiver is only adapted to the transmitted signal version and its output will be wasted due to non-matching with the received signal from the environment. The sidelobes amplitude of the matched filter output in pulse compression radars are dependent on the transmitted coded waveforms that extended as much as the length of the code on both sides of the target loc...

متن کامل

A Time-Domain Method for Shape Reconstruction of a Target with Known Electrical Properties (RESEARCH NOTE)

This paper uses a method for shape reconstruction of a 2-D homogeneous object with arbitrary geometry and known electrical properties. In this method, the object is illuminated by a Gaussian pulse, modulated with sinusoidal carrier plane wave and the time domains’ footprint signal due to object presence is used for the shape reconstruction. A nonlinear feedback loop is used to minimize the diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010