Performance Characterization of Amorphous Silicon Digital Detector Arrays for Gamma Radiography

نویسندگان

  • Rajashekar Venkatachalam
  • Venumadhav Vedula
  • Debasish Mishra
چکیده

This paper reports the performance characteristics of a-Si detectors with Ir-192 gamma source. Imaging performance of the detector system is evaluated using contrast sensitivity over a range of material thickness of steel, signal to noise ratio, dynamic range and linearity. The radiographic sensitivity was observed over a range of thickness of steel using standard image quality indicators. Quantum efficiency of the scintillator material (CsI) for Ir-192 and Co-60 was studied using theoretical models. For Ir-192 source both theoretical models and experiments were performed to find the minimum and maximum thickness limitation for steel using the a-Si detector system. Various configurations of pipe weld with defects such as lack of fusion, penetration, tungsten inclusion and porosities were studied to evaluate the imaging performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amorphous Silicon Flat Panel Imagers for Medical Application

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

X-ray detectors for digital radiography.

Digital radiography offers the potential of improved image quality as well as providing opportunities for advances in medical image management, computer-aided diagnosis and teleradiology. Image quality is intimately linked to the precise and accurate acquisition of information from the x-ray beam transmitted by the patient, i.e. to the performance of the x-ray detector. Detectors for digital ra...

متن کامل

Evaluation of New Digital Detectors for High Resolution Radiography

Abstract: In the actual study, two digital detectors were investigated : an amorphous silicon flat panel and a TDI multilinear detector. The contrast and IQI sensitivity was selected to compare flat panel and film radiography. The influence of X-ray conditions was assessed in the case of flat panel. Spatial resolution of both digital detectors was assessed by adapting the geometrical magnificat...

متن کامل

Comparison of Thermal Detector Arrays for Off-Axis THz Holography and Real-Time THz Imaging

In terahertz (THz) materials science, imaging by scanning prevails when low power THz sources are used. However, the application of array detectors operating with high power THz sources is increasingly reported. We compare the imaging properties of four different array detectors that are able to record THz radiation directly. Two micro-bolometer arrays are designed for infrared imaging in the 8...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006