Transcranial magnetic stimulation is investigated as a new tool in the therapy of depression and other psychiatric disorders. In almost all studies, the dorsolateral prefrontal cortex (DLPFC) has been selected as the target site for stimulation. Usually this region was determined by identifying the patient's motor cortex, and from there the coil was placed 5 cm rostrally. The aim of our study was to test the reliability of this standard procedure. A neuronavigational system was used to relate the final coil position after applying the standard procedure to the individual cortical anatomy. In 7 of 22 subjects, the Brodman area 9 of the DLPFC was targeted correctly in this manner. In 15 subjects, the center of the coil was found to be located more dorsally (e.g., above the premotor cortex). The current method for locating the DLPFC is not precise anatomically and may be improved by navigating procedures taking individual anatomy into account.
منابع مشابه
Towards localization of transcranial magnetic stimulation inside the MRI scanner
Background and Motivations: Transcranial magnetic stimulation (TMS) has been used as a non-invasive tool in various neuroscience applications including investigating brain functions, serving as a clinical diagnostic tool and as a therapy for several neuropsychiatric disorders [1]. TMS delivers time-pulse magnetic fields created by special coils to induce local currents in the tissue i.e., neuro...
متن کاملThe impact of repetitive navigated transcranial magnetic stimulation coil positioning and stimulation parameters on human language function
BACKGROUND Repetitive navigated transcranial magnetic stimulation (rTMS) in combination with object naming is able to elicit naming errors by stimulating language-related brain regions. However, stimulation results mainly depend on coil positioning and stimulation parameters, which have not been investigated since the implementation of neuronavigation to transcranial magnetic stimulation. There...
متن کاملDevelopment and positioning reliability of a TMS coil holder for headache research.
OBJECTIVE Accurate and reproducible coil positioning is important for headache research using transcranial magnetic stimulation protocols. We aimed to design a transcranial magnetic stimulation coil holder and demonstrate reliability of test-retest coil positioning. METHODS A coil holder was developed and manufactured according to three principles of stability, durability, and three-dimension...
متن کاملIndividualized rTMS neuronavigated according to regional brain metabolism (FGD PET) has better treatment effects on auditory hallucinations than standard positioning of rTMS: a double-blind, sham-controlled study
Low-frequency repetitive transcranial magnetic stimulation (LF-rTMS) of the left temporo-parietal cortex (LTPC) has been proposed as a useful therapeutic method for auditory hallucinations (AHs). Stereotactic neuronavigation enables the magnetic coil to be targeted according to the individual parameters obtained from neuroimaging. Individualized rTMS neuronavigated according to 18-fluorodeoxygl...
متن کاملOptimizing Functional Accuracy of TMS in Cognitive Studies: A Comparison of Methods
Transcranial magnetic stimulation (TMS) is a tool for inducing transient disruptions of neural activity noninvasively in conscious human volunteers. In recent years, the investigative domain of TMS has expanded and now encompasses causal structure-function relationships across the whole gamut of cognitive functions and associated cortical brain regions. Consequently, the importance of how to de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biological psychiatry
دوره 50 1 شماره
صفحات -
تاریخ انتشار 2001