Studies on performance of indices in cooling water system

نویسندگان

  • S Sathish Kumar
  • A Suriyanarayanan
  • S Panigrahi
چکیده

The usefulness and applicability of water indices such as Langelier saturation index, Ryznar stability index and Practical scale index for predicting the corrosive/scale forming tendency of chemically treated open recirculating cooling water has been studied. The study is based on the obtained corrosion and scale data for the period from May 1998 to December 2007, carried out at Fast Breeder Test Reactor, Kalpakkam, India. All the indices are calculated using pH, calcium, total dissolved solids, temperature and alkalinity of cooling water. Practical scale index and Ryznar stability index are found to be more informative than Langelier Saturation Index in keeping track of the corrosive/scaling tendency of the cooling water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of the performance of a solar adsorption cooling system

This article presents a transient model of a solar adsorption cooling system. A computer program has been developed to simulate the operation of a two bed silica gel- water adsorption cooling system as well as flat plate collectors and the hot water storage tank. This program is then utilized to simulate the performance of a sample solar adsorption cooling system used for cooling a set of r...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Enhancement Performance New Generation of CPU Cooling System Using Water-AL2O3 Nanofluid

By increase in the power of computer systems and enhanced power of the components and their temperature, including the central processing unit (CPU), cooling just by the air is not effective and there is need for more powerful systems to cool down and increase the power of the cooling system. In this article simulation of the heat exchanger material of the fluid cooling system has been studied ...

متن کامل

Experimental Investigation of Heat Transfer Enhancement in a Finned U-Shaped Heat Pipe of CPU Cooling System Using Different Fluids

This paper experimentally studies the heat absorption performance of a heat sink with vertical embedded heat pipes in the aluminum blade. The cooling system with embedded heat pipes distributes heat from the CPU to both the base plate and the heat pipes, and then transfer heat from fins to the Environment. The thermal resistance and heat transfer coefficient are evaluated for natural convection...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012