Cup revision involving retention of a fixed but malpositioned acetabular component in patients with poor general conditions
نویسندگان
چکیده
This study evaluated the surgical technique and outcomes of cup revision involving retention of a fixed but malpositioned acetabular component in patients with poor general conditions.Between 2007 and 2013, we performed cup revision on 12 hips while retaining a fixed (either cemented or uncemented) but malpositioned acetabular component. Indications for this technique were: malpositioned but fixed acetabular shell; sufficient space for the insertion of the prosthesis; and patients with poor general conditions. After intraoperative confirmation of shell stability, a replacement liner was oriented in a new plane. Clinical and imaging data were collected perioperatively and during follow-up for evaluation of surgical efficacy.No intraoperative complications were encountered. Mean operative duration was 70.4 minutes (range, 45-90 minutes) and mean estimated blood loss was 729 mL (range, 400-1200 mL). Mean follow-up duration was 5.1 years (range, 2.5-8.5 years). Average visual analog scale score decreased from (7.08 ± 1.00) preoperatively to (1.42 ± 0.67) at final follow-up (P < .05). Average Harris Hip Score improved from (14.7 ± 6.58) preoperatively to (80.9 ± 5.30) at final follow-up (P < .05). Anteversions and inclinations of new liners were (15.1 ± 2.3)° and (46.4 ± 3.9)° respectively. Postoperative radiographs showed no signs of prosthesis loosening, periprosthetic fractures, or dislocation compared with preoperatively.The short-term efficacy of cup revision with retention of a malpositioned but fixed acetabular component was satisfactory.
منابع مشابه
Isolated polyethylene exchange versus acetabular revision for polyethylene wear.
UNLABELLED Polyethylene wear and osteolysis are not uncommon in THA mid- and long-term. In asymptomatic patients the dilemma faced by the orthopaedic surgeon is whether to revise the cup and risk damage to the supporting columns and even pelvic discontinuity or to perform isolated polyethylene exchange and risk a high rate of postoperative recurrent instability and dislocation that will necessi...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملTreatment of Bilateral Recurrent Dislocation of Hip Pros-thesis with Malpositioned Well-Fixed Shell: A Case Report
Dislocations of total hip prostheses cause pain and patient dissatisfaction. Recurrent dislocations are difficult to treat mainly when the acetabular metal shell is well-fixed. The purpose of this article was to describe the surgical technique used for the treatment of a bilateral recurrent posterior dislocation after a cementless total hip prosthesis, caused by excessive inclination of acetabu...
متن کاملResults of single stage exchange arthroplasty with retention of well fixed cement-less femoral component in management of infected total hip arthroplasty
AIM To investigate success of one stage exchange with retention of fixed acetabular cup. METHODS Fifteen patients treated by single stage acetabular component exchange with retention of well-fixed femoral component in infected total hip arthroplasty (THA) were retrospectively reviewed. Inclusion criteria were patients with painful chronic infected total hip. The patient had radiologically wel...
متن کاملA technique to remove a well-fixed titanium-coated rm acetabular cup in revision hip arthroplasty
A major concern during revision hip arthroplasty is acetabular bone loss and bleeding during the extraction of well-fixed cementless acetabular cup, because no interface exists between the host bone and the cup. Forceful removal of such component using curved gouges and osteotomes often leads to extended bone loss and compromises reimplantation of a new socket. In the following case report, we ...