Comparison of the diagnostic yields of disposable and reusable cytology brushes in fibreoptic bronchoscopy.

نویسندگان

  • W J Kinnear
  • M J Wilkinson
  • P D James
  • I D Johnston
چکیده

Disposable rake and reusable bristle type cytology brushes have been compared in 50 patients undergoing fibreoptic bronchoscopy for suspected malignancy. Forty seven patients were eventually found to have carcinoma of the bronchus. A diagnosis of malignancy was made from the specimens taken with one or other brush in 34 patients, from the reusable brush in 28, and from the disposable brush in 31. The specimens taken with the two types of brush were of similar quality. The reusable brush is about five times less expensive per procedure but carries a risk of cross contamination and cross infection, and time is needed to clean the brush after each bronchoscopy. The diagnostic yield appears to be at least as good with the disposable brush.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of morphological diagnosis of lung cancer in a department of respiratory medicine.

In view of the importance of determination of cell type in patients with bronchial carcinoma who are to be given chemotherapy a series of 140 histologically proved cases was analysed to assess the accuracy of pretreatment diagnosis by cytology and bronchial biopsy. Final histological diagnosis was made after thoracotomy (131 cases) or necropsy (9 cases). Before treatment, malignancy was diagnos...

متن کامل

Fibreoptic bronchoscopy today: a review of 255 cases.

An analysis of 255 fibreoptic bronchoscopies showed that the major indication for bronchoscopy was suspected bronchial carcinoma (93% of cases). Of the 183 patients finally shown to have bronchial carcinoma 83% had abnormal bronchoscopy findings and 65% had bronchial biopsy specimens diagnostic of malignancy. These figures were superior to those obtainable with rigid bronchoscopy, particularly ...

متن کامل

Sequential brush biopsy and conventional biopsy: direct comparison of diagnostic sensitivity in lung malignancy.

One hundred and sixteen patients with suspected lung malignancy who were referred for bronchoscopy were examined using both the flexible fibreoptic bronchoscope and the rigid bronchoscope. Both instruments were used sequentially under the same general anaesthetic. Brush biopsies were obtained through the fibreoptic bronchoscope and conventional biopsies, for histological examination, through th...

متن کامل

Diagnostic Accuracy of Frozen Section in Comparison With Fine Needle Aspiration Cytology in Thyroid Lesions – A Prospective Study

Background and Objectives: Thyroid gland because of its superficial location is amenable to direct physical examination. Clinical assessment of thyroid lesions by means of physical examination, thyroid scans and ultrasonography is not completely reliable. Fine needle aspiration cytology (FNAC) is the most cost-effective, safe and an initial diagnostic test in the pre-operative evaluation of thy...

متن کامل

Comparison of bronchial brushing, washing and forceps biopsies in diagnosis of bronchogenic carcinoma

  Five hundred eighty patients underwent diagnostic flexible fiberoptic bronchoscopy: during June 1988 to March 1993 at the bronchoscopy center of Kerman university of medical sciences. Seventy six specimens were obtained from patients with bronchogenic carcinoma and 155 from patients with benign disease of the lung. The efficiency of brushing and washing techniques was compared with forceps b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 46 9  شماره 

صفحات  -

تاریخ انتشار 1991