Biomechanical characteristics of microimplant for anchorage in orthodontics: a 3D finite element model study.
نویسندگان
چکیده
In orthodontic treatment, anchorage control is essential for success. A recent development, stationary anchorage (micro- implants) eliminates one of the uncertainties of orthodontic tooth movement by offering absolute control over potentially undesirable counter movements. The objective of this study was to establish a 3D finite element model for microimplant and to analyze the influence of different angulations to the long axis of the teeth (30-90°) on the biomechanical characteristics of orthodontic anchorage implant-bone interface. Results of this study showed that largest stress and deformation was seen in the cortical bone and upper region of trabecular bone. Stress and deformation increased as the angulations of the implant to the long axis of the tooth increased. As the angulation of the implant to the long axis of maxillary 1st molar increased, stress and deformation also decreased. Maximum stress and displacement were recorded when implant was placed perpendicular to the long axis of maxillary 1st molar.
منابع مشابه
Second Molar Uprighting with Temporary Anchorage Devices: A Finite Element Study
BACKGROUND AND OBJECTIVE: Premature loss of mandibular first molar is a common problem in adults. Mesial tipping of second molar may occur in this situation. Various orthodontic mechanics have been proposed for molar uprighting. The aim of this study was to compare four methods of molar uprighting using Finite Element Analysis(FEM). METHODS: In first model of this finite element study, a 0.019...
متن کاملA study on behavior of block pavement using 3D finite element method
Three dimensioned finite element analysis were conducted on concrete block paving. In order to verify the calculated results, an experimental case study was analyzed. Good agreement was observed between the measured and the calculated results. Based on the finite element analysis results and available failure models, comprehensive design charts were developed for port and industrial pavement wh...
متن کاملA Super - Element Based on Finite Element Method for Latticed Columns Computational Aspect and Numerical Results
This paper presents a new super-element with twelve degrees of freedom for latticed columns. This elements is developed such that it behaves, with an acceptable approximation, in the same manner as a reference model does. The reference model is constructed by using many Solid elements. The cross section area, moments of inertia, shear coefficient and torsoinal rigidity of the developed new elem...
متن کاملA Super - Element Based on Finite Element Method for Latticed Columns Computational Aspect and Numerical Results
This paper presents a new super-element with twelve degrees of freedom for latticed columns. This elements is developed such that it behaves, with an acceptable approximation, in the same manner as a reference model does. The reference model is constructed by using many Solid elements. The cross section area, moments of inertia, shear coefficient and torsoinal rigidity of the developed new elem...
متن کامل[A three-dimensional finite element analysis for the biomechanical characteristics of orthodontic anchorage micro-implant].
PURPOSE To establish a three-dimensional finite element model for orthodontic anchorage micro-implant,and to analyze the influence of different titled angles on the biomechanical characteristics of orthodontic anchorage implant-bone interface. METHODS ANSYS(Analysis System)finite element analysis software was used to perform the finite element modeling of the micro-implant with 7 different ti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of contemporary dental practice
دوره 14 6 شماره
صفحات -
تاریخ انتشار 2013