Repeatability and Accuracy of Bone Cutting and Ankle Digitization in Computer-Assisted Total Knee Replacements

نویسندگان

  • Kevin B. Inkpen
  • Antony J. Hodgson
  • Christopher Plaskos
  • Cameron A. Shute
  • Robert W. McGraw
چکیده

In conventional total knee replacement (TKR) surgery, a significant fraction of implants have varus/valgus alignment errors large enough to reduce the lifespan of the implant, so we are developing a more accurate computer-assisted procedure aimed at reducing the standard deviation (SD) of the implant’s frontal alignment to under 1? . In this study we measured the contributions to overall alignment error of two steps in our proposed procedure: ankle digitization and manual bone cutting. We introduce a new digitizing probe that quickly and robustly locates the midpoint between the ankle malleoli. Based on repeated measurements on 8 cadavers by 6 operators (318 measurements), we estimate that the new probe introduces only 0.15? (SD) of variability into the definition of the tibial mechanical axis in the frontal plane. We also measured the accuracy and repeatability with which surgeons can implement a bone cut using conventional cutting guides to see if conventional cutting techniques are sufficiently accurate. A total of 53 tibial plateau, distal and anterior/posterior (A/P) femoral cuts approximated primary and revision TKR resections. In 20 test cuts on cadaver bone made by 2 expert TKR surgeons, we found a SD of 0.37? (bias of 0.29?) in the varus/valgus difference between the guide orientation and the implant orientation before cementing, but in 23 additional cuts performed by four less-experienced surgeons, the SD was 0.83? (bias of 0.31?). Ten A/P femoral cuts showed similar trends. We conclude that, in the hands of an experienced surgeon, our current technique (based on our previously-reported non-invasive hip centre locating technique [Inkpen 1999b], robust ankle digitization and manual cutting using computer-guided cutting guides) can approach our target alignment variability goal of a SD less than 1? .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Restoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases

Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...

متن کامل

Cutting Errors in Total Knee Replacement: Assessment by Computer Assisted Surgery

The observed errors in the position of the implanted prosthesis can be due to a number of potential causes. One of these is the potential error during execution of the bone cuts. However, there is only minimal information on this in the current literature. The amount of cutting errors in forty consecutive total knee replacements was reported. All the operations were done by the same surgeon. Th...

متن کامل

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation

Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...

متن کامل

Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement

BACKGROUND In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. METHODS A compara...

متن کامل

Distal Femoral Valgus Cut Errors in Total Knee Replacement

The causes of malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides (1). We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000