Biomechanical effects of bone-implant fitness and screw breakage on the stability and stress performance of the nonstemmed hip system.
نویسندگان
چکیده
BACKGROUND Some nonstemmed hip systems have been developed to avoid stress shielding and aseptic loosening, which are major drawbacks of stemmed hip arthroplasty. Without the stem, the cup over the femoral head can be stabilized by anatomic fitness of the cup interior and mechanical fixation of the auxiliary screws. METHODS Using finite-element method, neck-shaped systems with two bone-cup fitness situations and four types of screw breakages are systematically investigated to evaluate their biomechanical effects on construct performances. The construct stresses and interfacial micromotion were chosen for comparison between two bone-cup fitness situations and four types of screw breakages. FINDINGS The screw breakage deteriorates the stresses of the mating screw and the neck cup and loosens the bone-cup interfaces. The breakages of central and locking screws decrease the bone stress by about 43.2% and 12.7%, respectively. This indicates that the central screw is a more effective load-bearer for the superimposed cup than the locking screw. As compared with the fitting cup, the stress of cup and the bone stresses of the unfitting cup obviously increase. This demonstrates that the load-transferring path at the cup bottom is important in directly relieving the prosthetic stresses. INTERPRETATION Any screw design inducing stress concentration should be validated to avoid screw breakage. Comparatively, surgical unfitness has a more significant effect on the construct performance than does the screw breakage. Even for custom-made cups, cautious preparation of the neck resection is still necessary to ensure intimate bone-cup contact.
منابع مشابه
Effects of stemmed and nonstemmed hip replacement on stress distribution of proximal femur and implant
BACKGROUND Despite improvements in shape, material, and coating for hip stem, both stress shielding and aseptic loosening have been the major drawbacks of stemmed hip arthroplasty. Some nonstemmed systems were developed to avoid rasping off the intramedullary canal and evacuating the bone marrow due to stem insertion. METHODS In this study, the finite-element models of one intact, one stemmed...
متن کاملThe clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study
The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملمطالعه تنشهای اطراف ایمپلنت به روش اجزای محدود در بریجهای با ساپورت دندان/ایمپلنت در شرایط اتصال سخت و غیرسخت در پروتزهای سمان شونده
Background and Aims: Freestanding fixed partial prosthesis is considered the first choice whenever possible. However, anatomical limitations for implants and other reasons may create situation in which it would be preferable to connect the implants to teeth. A biomechanical dilemma in a tooth/implant-supported system comes from dissimilar mobility. This disparity cause the bridge to function as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical biomechanics
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2014