Bacteriophage Can Prevent Encrustation and Blockage of Urinary Catheters by Proteus mirabilis.
نویسندگان
چکیده
Proteus mirabilis forms dense crystalline biofilms on catheter surfaces that occlude urine flow, leading to serious clinical complications in long-term catheterized patients, but there are presently no truly effective approaches to control catheter blockage by this organism. This study evaluated the potential for bacteriophage therapy to control P. mirabilis infection and prevent catheter blockage. Representative in vitro models of the catheterized urinary tract, simulating a complete closed drainage system as used in clinical practice, were employed to evaluate the performance of phage therapy in preventing blockage. Models mimicking either an established infection or early colonization of the catheterized urinary tract were treated with a single dose of a 3-phage cocktail, and the impact on time taken for catheters to block, as well as levels of crystalline biofilm formation, was measured. In models of established infection, phage treatment significantly increased time taken for catheters to block (∼ 3-fold) compared to untreated controls. However, in models simulating early-stage infection, phage treatment eradicated P. mirabilis and prevented blockage entirely. Analysis of catheters from models of established infection 10 h after phage application demonstrated that phage significantly reduced crystalline biofilm formation but did not significantly reduce the level of planktonic cells in the residual bladder urine. Taken together, these results show that bacteriophage constitute a promising strategy for the prevention of catheter blockage but that methods to deliver phage in sufficient numbers and within a key therapeutic window (early infection) will also be important to the successful application of phage to this problem.
منابع مشابه
Prevention of encrustation and blockage of urinary catheters by Proteus mirabilis via pH-triggered release of bacteriophage
The crystalline biofilms of Proteus mirabilis can seriously complicate the care of patients undergoing long-term indwelling urinary catheterisation. Expression of bacterial urease causes a significant increase in urinary pH, leading to the supersaturation and precipitation of struvite and apatite crystals. These crystals become lodged within the biofilm, resulting in the blockage of urine flow ...
متن کاملA sensor to detect the early stages in the development of crystalline Proteus mirabilis biofilm on indwelling bladder catheters.
A simple sensor has been developed to detect the early stages of urinary catheter encrustation and avoid the clinical crises induced by catheter blockage. In laboratory models of colonization by Proteus mirabilis, the sensor signaled encrustation at an average time of 43 h before catheters were blocked with crystalline biofilm.
متن کاملDevelopment of an antimicrobial urinary catheter to inhibit urinary catheter encrustation
Background: Encrustation of urinary catheters is a frequent problem in patients with long-term indwelling catheters colonised with urease-positive bacteria such as Proteus mirabilis. Catheter blockage may follow catheter encrustation, potentially leading to systemic infection. Prevention of encrustation is difficult and avoidance of recurrence often unsuccessful. One possible preventative strat...
متن کاملEffect of triclosan on the formation of crystalline biofilms by mixed communities of urinary tract pathogens on urinary catheters.
The crystalline bacterial biofilms that encrust Foley catheters compromise the care of many elderly and disabled patients. The aim of this study was to examine whether the biocide triclosan can prevent encrustation by the mixed flora of uropathogens that commonly infect patients undergoing long-term catheterization. Models of the catheterized bladder were inoculated with communities of organism...
متن کاملControl of encrustation and blockage of Foley catheters.
Urinary catheters often become encrusted and blocked by crystalline Proteus mirabilis biofilms. Results of experiments in a laboratory model of a Foley catheterised bladder infected with P mirabilis showed that when retention balloons were inflated with a solution of triclosan (10 g/L), the catheters drained freely for at least 7 days. Triclosan became impregnated throughout the silicone cathet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 60 3 شماره
صفحات -
تاریخ انتشار 2015