Sternal reconstruction with titanium plates in complicated sternal dehiscence.

نویسندگان

  • Bernhard Voss
  • Robert Bauernschmitt
  • Albrecht Will
  • Markus Krane
  • Ruth Kröss
  • Gernot Brockmann
  • Paul Libera
  • Rüdiger Lange
چکیده

OBJECTIVE Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. The use of titanium plates is a promising approach for sternal reconstruction. METHODS Titanium plate fixation was used in 15 patients (67+/-5.9 years, 171+/-8.2 cm, 93.6+/-14.9 kg, body mass index 32+/-5 kg/m(2)) with unstable thorax after failed attempts of sternal closure and patients in whom failure of conventional rewiring would be expected due to one or more serious risk factors (e.g. multiple fractures or loss of sternum, excessive overweight). In six patients, one of whom had an infection, the Synthes Titanium Sternal Fixation System was used as transverse plate fixation (series 1). In nine other patients, longitudinal titanium plating of the sternum was performed with 2.4mm Synthes locking reconstruction plates, which were cross-connected by wires (series 2). In six of these patients the cross-connection was reinforced by additional short transverse plates. In series 2, sternal instability was complicated by multiple fragments of sternum (n=8) and/or infection (n=3). In case of infection, initial debridement was performed with consecutive antibiotic and topical negative pressure therapy (median 13 days). Clinical examination was done 3-12 months postoperatively. RESULTS Mean operation time was 133+/-21 min (series 1) and 110+/-12 min (series 2). Transverse plating required more extensive mobilization of pectoral muscle. All patients had an uneventful early postoperative course and were extubated 5.1+/-5.9h (median 4 h) after surgery. Postoperatively, all patients had a stable thorax, but in the long-term three patients from series 1 complained of plate-related pain during breathing, with the subsequent need of plate removal. One multi morbid patient from series 1 died on the 31st postoperative day. The cause of death was not related to the sternal plate refixation. CONCLUSION Titanium plate fixation is an effective method to stabilize complicated sternal dehiscence. The longitudinal plating technique is easier to apply and seems to be associated with fewer complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complicated sternal dehiscence treated with the strasbourg thoracic osteosyntheses system (STRATOS) and the transposition of greater omentum: a case report

Sternal dehiscence is a serious complication after cardiac surgery. Sternal refixation, performed by simple rewiring or techniqual modification of rewiring as described by Robicsek, can fail, overall when the bone quality is poor or the sternum is completely destroyed. The sternal closure systems, consisting of plates, screws or rib clips and titanium bars, have been recently introduced to trea...

متن کامل

Titanium Plate Fixation for Sternal Dehiscence in Major Cardiac Surgery

BACKGROUND Sternal dehiscence is one of the most troublesome complications following cardiac surgery. Treatment failure and consequent lethal outcomes are very common. The aim of this study was to evaluate titanium plate fixation as a treatment for sternal dehiscence following major cardiac surgery. MATERIALS AND METHODS Between 2010 and 2012, 17 patients underwent sternal reconstruction usin...

متن کامل

Sternal Wound Reconstruction with Porcine Acellular Dermal Matrix (strattice) for Poststernotomy Mediastinitis

Sternal reconstruction could be a complex and challenging procedure. Common indications are defects after heart surgery, infections, tumour ablation, radiation necrosis, congenital deformities and trauma. Aloplastic materials are often used for sternal stabilization and regional aps are applied to provide well vascularized soft tissue coverage. Although numerous materials are available, acellul...

متن کامل

Sternal plate fixation for sternal wound reconstruction: initial experience (Retrospective study)

BACKGROUND Median sternotomy infection and bony nonunion are two commonly described complications which occur in 0.4-5.1% of cardiac procedures. Although relatively infrequent, these complications can lead to significant morbidity and mortality. The aim of this retrospective study is to evaluate the initial experience of a transverse plate fixation system following wound complications associate...

متن کامل

Use of titanium plate fixation system in late sternal dehiscence repair

Sternal instability with mediastinitis is a very serious complication after median sternotomy. Sternal dehiscence repair together with debridement of the infected tissue is the mainstay of therapy where various modalities are employed. Here, we report the use of titanium plate for sternum stabilization in a patient with sternal dehiscence and superficial wound infection.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2008