Correlation of continuous-wave Doppler spectral flow analysis with gross pathology in carotid stenosis.

نویسندگان

  • G K Call
  • W M Abbott
  • N R Macdonald
  • J Megerman
  • K R Davis
  • R C Heros
  • J P Kistler
چکیده

Preoperative continuous-wave Doppler spectral analysis was used to generate two parameters, peak frequency in the internal carotid artery (fmax) and the ratio of peak frequencies in the internal and common carotid arteries (carotid index). These were compared with direct measurement of residual lumen diameter in pathologic specimens obtained from carotid endarterectomy in 37 patients. Doppler shift frequency parameters were well correlated with residual lumen diameter when the latter was at least 1 mm. Residual lumens of less than or equal to 2 mm were found to have an fmax of greater than 7.5 kHz and a carotid index of greater than 3.8. If fmax was greater than 14 kHz or the carotid index was greater than 7, the residual lumen diameter was nearly always less than or equal to 1 mm. Thus, the severity of the stenosis correlated directly with Doppler shift frequencies. The length of stenoses did not affect the correlations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Between-method correlation in quantifying internal carotid stenosis.

BACKGROUND AND PURPOSE The degree of internal carotid stenosis has emerged as the most important predictor of ischemic stroke in extracranial carotid artery disease. The purpose of this study was to assess the validity of the noninvasive techniques for quantifying internal carotid stenosis with respect to the accepted standard of intra-arterial angiography. METHODS We measured the maximum per...

متن کامل

Candida patients in a Jorjani center in Shahid Mohammadi Hospital of carotid Doppler sonnograghy findings in coronary artery Bypas grafting Bandar Abbas

Introduction: Nowadays caotid Dopplers sonography is gold standard for carotid artery screening in coronary aetery bypass grafting (CABG) candidates. This study was carried out in an angioplasty center in southern seaport in Iran to assesss theprevalence of artery stenosis and correlation of the atherosclerosis risk factor with the rate of artery stensis, and nence to define the high risk group...

متن کامل

Power M-Mode Doppler and single-gate spectral analysis using a 2-MHz pulsed-wave Doppler transducer to directly detect cervical internal carotid artery stenosis: use of the continuity principle: report of a novel technique.

BACKGROUND AND PURPOSE We hypothesized that direct cervical investigation with Power M-Mode Doppler (PMD) combined with single-gate Doppler spectral analysis (SGDSA) using a 2-MHz pulsed-wave Doppler transducer would show reasonable accuracy parameters when compared with standard color-coded carotid duplex ultrasound (CDU). METHODS We prospectively screened for cervical internal carotid arter...

متن کامل

Quantitation of carotid stenosis with continuous-wave (C-W) Doppler ultrasound.

Two methods for determining the degree of stenoses developing on the origin of the internal carotid were tested using non-invasive Doppler ultrasonic imaging (DOPSCAN) of the carotid bifurcations. Spectral analysis of Doppler audio recordings was utilized in determining the maximum frequencies found within the stenosis, as well as the ratio of the frequency downstream to the stenosis, to the fr...

متن کامل

Continuous wave Doppler ultrasonography in the detection of carotid stenosis and occlusion.

Directional continuous wave Doppler ultrasonography has been used to assess the extracranial carotid arteries of over 500 patients, 90 of whom have had angiography performed. The angiographic and Doppler findings are compared, showing that this simple ultrasound technique is able to detect carotid stenosis and occlusion, but is unreliable in the detection of mild atheromatous change. In this se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 19 5  شماره 

صفحات  -

تاریخ انتشار 1988