Antibiotic Spacers in Shoulder Arthroplasty: Comparison of Stemmed and Stemless Implants
نویسندگان
چکیده
Background Antibiotic spacers in shoulder periprosthetic joint infection deliver antibiotics locally and provide temporary stability. The purpose of this study was to evaluate differences between stemmed and stemless spacers. Methods All spacers placed from 2011 to 2013 were identified. Stemless spacers were made by creating a spherical ball of cement placed in the joint space. Stemmed spacers had some portion in the humeral canal. Operative time, complications, reimplantation, reinfection, and range of motion were analyzed. Results There were 37 spacers placed: 22 were stemless and 15 were stemmed. The stemless spacer population was older (70.9 ± 7.8 years vs. 62.8 ± 8.4 years, p = 0.006). The groups had a similar percentage of each gender (stemless group, 45% male vs. stemmed group, 40% male; p = 0.742), body mass index (stemless group, 29.1 ± 6.4 kg/m2 vs. stemmed group, 31.5 ± 8.3 kg/m2; p = 0.354) and Charlson Comorbidity Index (stemless group, 4.2 ± 1.2 vs. stemmed group, 4.2 ± 1.7; p = 0.958). Operative time was similar (stemless group, 127.5 ± 37.1 minutes vs. stemmed group, 130.5 ± 39.4 minutes). Two stemless group patients had self-resolving radial nerve palsies. Within the stemless group, 15 of 22 (68.2%) underwent reimplantation with 14 of 15 having forward elevation of 109° ± 23°. Within the stemmed group, 12 of 15 (80.0%, p = 0.427) underwent reimplantation with 8 of 12 having forward elevation of 94° ± 43° (range, 30° to 150°; p = 0.300). Two stemmed group patients had axillary nerve palsies, one of which self-resolved but the other did not. One patient sustained dislocation of reverse shoulder arthroplasty after reimplantation. One stemless group patient required an open reduction and glenosphere exchange of dislocated reverse shoulder arthroplasty at 6 weeks after reimplantation. Conclusions Stemmed and stemless spacers had similar clinical outcomes. When analyzing all antibiotic spacers, over 70% were converted to revision arthroplasties. The results of this study do not suggest superiority of either stemmed or stemless antibiotic spacers.
منابع مشابه
Functional midterm follow-up comparison of stemless total shoulder prostheses versus conventional stemmed anatomic shoulder prostheses using a 3D-motion-analysis
BACKGROUND The aim of this study is to compare the functional midterm outcome of stemless shoulder prostheses with standard anatomical stemmed shoulder prostheses and to show that the STEMLESS results are comparable to the STEMMED with respect to active maximum range of shoulder motion (ROM) and Constant score (CS). METHODS Seventeen patients underwent total shoulder arthroplasty (TSA) in 25 ...
متن کاملAre there differences between stemless and conventional stemmed shoulder prostheses in the treatment of glenohumeral osteoarthritis?
BACKGROUND Conventional stemmed anatomical shoulder prostheses are widely used in the treatment of glenohumeral osteoarthritis. The stemless shoulder prosthesis, in contrast, is a new concept, and fewer outcome studies are available. Therefore, the purpose of the study was to investigate the early functional outcome and postoperative proprioception of a stemless prosthesis in comparison with a ...
متن کاملRadiological changes do not influence clinical mid-term outcome in stemless humeral head replacements with hollow screw fixation: a prospective radiological and clinical evaluation
BACKGROUND Stemless shoulder arthroplasty is a fairly new concept. Clinical and radiological follow-up is essential to prove implant safety and concept. This prospective single-centre study was performed to evaluate the influence of radiological changes on clinical mid-term outcome following stemless humeral head replacement with hollow screw fixation. METHODS Short- and mid-term radiological...
متن کاملFretting and Corrosion in Modular Shoulder Arthroplasty: A Retrieval Analysis
Tribocorrosion in taper junctions of retrieved anatomic shoulder arthroplasty implants was evaluated. A comparison of the tribocorrosion between cobalt-chromium and titanium alloy stems was conducted and the observations were correlated with the individual's clinical data. Adverse effects caused by metal debris and subsequent elevated serum metal ion levels are frequently reported in total hip ...
متن کاملAnatomic stemless shoulder arthroplasty and related outcomes: a systematic review
BACKGROUND The latest generation of shoulder arthroplasty includes canal-sparing respectively stemless designs that have been developed to allow restoration of the glenohumeral center of rotation independently from the shaft, and to avoid stem-related complications. The stemless prosthesis design has also recently been introduced for use in reverse arthroplasty systems. METHODS We systematica...
متن کامل