Using a Substitution Measurement Topology to Eliminate the Effect of Common Mode Errors in Resistance Measurements used in Temperature Metrology

نویسنده

  • Paul Bramley
چکیده

This article discusses the advantages of using a substitution measurement topology in place of the conventional common-current series connection arrangement employed in bridges or potentiometric resistance instruments working at the highest (sub ppm) accuracies. Most high accuracy resistance instruments pass a common AC or DC current through the device-under-test (DUT) and a reference standard (REF). The ratio of the resistance of the DUT to that of the REF is determined by balancing a bridge circuit or by taking successive measurements of the voltage across the DUT and REF with a highly linear voltmeter. However, both these techniques are prone to the effect of common-mode signals in the bridge circuit or the differential amplifier used with the voltmeter. An alternative measurement topology is discussed in which the DUT and REF are alternately switched into the same measurement point in the instrument in order avoid common mode changes between measurements on the REF and DUT. Unfortunately, this approach significantly increases the performance demands on the current source used to generate the sense current and this would normally result in comparable errors to those from the commonmode problems we are trying to overcome. However, by using a cascode amplifier between the current source and the measurement point and by employing active guarding this pitfall is avoided. This technique is employed in the new microK range of resistance bridges developed for temperature metrology applications. This paper and the performance results show how this technique allows the instruments to take full advantage of the high linearity and speed of the ADC developed for the products in order to achieve sub milli-Kelvin uncertainties. Although this paper discusses the application of the principle to resistance measurement, it can equally be applied to the measurement of other parameters such as capacitance or inductance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using a Temperature Gradient against the Time in Polyacrylamide Gel Electrophoresis May Eliminate the Need for Stacking Gels

Background and Objectives: Making stacking gels for polyacrylamide gels in the laboratory by conventional methods is laborious and time consuming. Considering the role of temperature in polyacrylamide gels with respect to electrical resistance and viscosity, we assumed that decreasing the temperature would cause an increase in electrical resistance and viscosity.  Ultimately, a downward tempera...

متن کامل

Design and Implementation of a Kalman Filter-Based Time-Varying Harmonics Analyzer

Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...

متن کامل

The Effect of Measurement Errors on the Performance of Variable Sample Size and Sampling Interval Control Chart

The effect of measurement errors on adaptive and non-adaptive control charts has been occasionally considered by researchers throughout the years. However, that effect on the variable sample size and sampling interval (VSSI) control charts has not so far been investigated. In this paper, we evaluate the effect of measurement errors on the VSSI control charts. After a model development, the effe...

متن کامل

Analyzing the Effect Adding an Active Feedback Network with an Inductive behavior to a Common-Gate Topology as a Transimpedance Amplifier for Low-Power and Wide-Band Communication Applications

  Common Gate (CG) topologies are commonly used as the first stage in Transimpedance Amplifiers (TIA), due to their low input resistance. But, this structure is not solely used as a TIA and comes with other topologies such as differential amplifiers or negative resistances and capacitances. This paper deals with analyzing the effect of adding an active feedback network to a common gate topology...

متن کامل

Error Recovery by the Use of Sensory Feedback and Reference Measurements for Robotic Assembly

Industrial robots need instrument or parts transport to do which requires coordinate to show the robot’s instrument, parts and body. When investigating the robot location, we are usually interested in measuring its location relative to a reference coordinate system. In this system it is attempted to make the assemble direction smaller by designing the sensor board and making use of an instrumen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014