Reference intervals for a complete blood count determined on different automated haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120.

نویسندگان

  • Jan Van den Bossche
  • Katrien Devreese
  • Ronald Malfait
  • Martine Van de Vyvere
  • Annick Wauters
  • Hugo Neeis
  • Pieter De Schouwer
چکیده

We processed 317 samples from healthy adult volunteers for a complete blood count, including leukocyte differentials and reticulocyte parameters, through five new-generation haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120. From these data non-parametric 2.5-97.5 percentile reference intervals were calculated for all parameters on all analysers. Some differences were found compared with previously reported reference intervals. Reference intervals for platelet parameters and reticulocytes agreed with these usually accepted. For red blood cell parameters, including haemoglobin and haematocrit, and white blood cell count, including absolute white blood cell differentials, our calculated reference intervals were in agreement with less frequently cited earlier reports, but were lower compared to the usually accepted reference intervals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hematopathology / AUTOMATED METHODS FOR PERFORMING IMMATURE RETICULOCYTE FRACTION Five Fully Automated Methods for Performing Immature Reticulocyte Fraction Comparison in Diagnosis of Bone Marrow Aplasia

We performed a parallel evaluation of 5 automated reticulocyte counters to produce the immature reticulocyte fraction (IRF). We analyzed 225 samples from healthy control subjects, 115 from patients with various diseases, 38 with advanced aplasia, and 22 in early erythropoietic recovery after chemotherapy or bone marrow transplantation. The reference intervals were different for each instrument ...

متن کامل

Flow cytometric reticulocyte counting. Parallel evaluation of five fully automated analyzers: an NCCLS-ICSH approach.

We performed a parallel evaluation of 5 automated reticulocyte analyzers. The guidelines were those proposed by the National Committee for Clinical Laboratory Standards and the International Council for Standardisation in Haematology. Duplicate analyses were performed for 225 healthy subjects and 115 patients affected by various diseases. The reference intervals were different for each method (...

متن کامل

Comparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples.

Reliable automated blood cell characterization and quantification remain challenging in pathologic samples, whereas slide reviews due to unnecessary flagging should be avoided. We compared 4 modern hematology analyzers-Abbott Sapphire, Siemens Advia 120, Sysmex XE-2100, and Beckman Coulter DxH 800-regarding complete blood cell count (CBC), leukocyte differential count, and flagging efficacy in ...

متن کامل

Accuracy of platelet counting haematology analysers in severe thrombocytopenia and potential impact on platelet transfusion.

Although haematology analysers provide reliable full blood counts, they are known to be inaccurate at enumerating platelets in severe thrombocytopenia. If the thresholds for platelet transfusion, currently set at 10 x 10(9)/l, are to be further reduced, it is vital that the limitations of current analysers are fully understood. The aim of this large multicentre study was to determine the accura...

متن کامل

Automated counting of nucleated red blood cells in blood samples of newborns.

Nucleated red blood cells (NRBC) in blood samples interfere with the white blood cell (WBC) count on many types of automated haematology analysers. This makes it necessary to correct the WBC count by counting NRBC microscopically. This report describes the evaluation of two analysers, the Cell-Dyn 4000 and the Sysmex XE-2100, which use new techniques to recognize and enumerate NRBC. We conclude...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2002