Neutron Capture Measurements and Resonance Analysis of Dysprosium
نویسندگان
چکیده
Y.R. Kang, M.W. Lee, T.I. Ro, G.N. Kim, ∗ Y. Danon, and D. Williams Research Center, Dongnam Inst. of Radiological & Medical Sciences, Busan 619-953, Republic of Korea Department of Physics, Dong-A University, Busan 604-714, Republic of Korea Department of Physics, Kyungpook National University, Daegu 702-701, Republic of Korea Gaerttner LINAC Center, Rensselaer Polytechnic Institute Troy, New York 12180-3590, USA
منابع مشابه
Total and Capture Cross Sections of Dysprosium Isotopes up to 20 MeV
Neutron data for total and capture cross sections were evaluated on 160Dy, 161Dy, 162Dy, 163Dy, and 164Dy up to 20 MeV. The resolved resonance parameters were adopted from the Mughabghab compilation, but one bound level resonance for each isotope except 162Dy was invoked to reproduce the reference thermal cross sections. The average resonance parameters for s-wave neutrons were obtained from th...
متن کاملNeutron Capture and Transmission Measurements and Resonance Parameter Analysis of Niobium
Epithermal neutron capture and transmission measurements were performed using the timeof-flight method at the Rensselaer Polytechnic Institute linac using metallic Nb samples. The capture measurements were made at the 25-m flight station with a 16-section sodium iodide multiplicity detector and the transmission measurements at the 25-m flight station with a 6Li glass scintillation detector. Res...
متن کاملRietveld Texture Analysis by Neutron Diffraction of .highly Absorbing Materials
We discuss the impact of strong absorption for thermal neutrons on data analysis and compare absorption corrections in the GSAS and MAUD Rietveld codes for texture and structural parameter refinement. Diffraction data were collected on the neutron powder diffractometer HIPPO at LANSCE from dysprosium and erbium, which are moderate to strong absorbers for thermal neutrons with absorption cross-s...
متن کاملTitle Design of light element analysis system in BNCT and every NCT
Introduction: The Monte Carlo simulation is used to enhance reliability in the experiments related to nuclear instruments. in addition, that is used to calculate the different components of the neutron and gamma ray fluxes in boron neutron capture therapy(BNCT) and neutron capture (NCT)applications. BNCT is one of the methods in radiotherapy, that is used the neutron beam for ki...
متن کاملThe use of selected neutron absorption resonance filters to suppress spurious events on hot neutron spectrometers
Resonant absorption can be used as a filter for high energy neutron spectroscopy. Here we report the transmission of eight thin foil filters: erbium, indium, iridium, dysprosium, hafnium, gadolinium, cadmium and samarium, measured using neutron time-of-flight techniques over a range of energies (1 meV to 10 eV). Measured transmission is converted into energy-dependent absorption cross-section w...