Direct determination of cadmium in urine with use of a stabilized temperature platform furnace and Zeeman background correction.

نویسندگان

  • E Pruszkowska
  • G R Carnrick
  • W Slavin
چکیده

In this determination of Cd in urine, simple aqueous standards were used to which NaCl and the matrix modifier were added. The urine was diluted fivefold with water. The mean analytical recovery of added Cd for urine samples was 101%, with individual variations of less than 4%. We used the stabilized temperature platform furnace, Zeeman background correction, pyrolytically coated graphite tubes, and (NH4)2HPO4 plus HNO3 as a matrix modifier. The sensitivity of the method provided a characteristic amount of 0.35 pg of Cd per 0.0044 A X s, obtained with integrated absorbance readings. The absolute Cd detection limit in urine was 0.15 pg, corresponding to 0.04 microgram/L of urine. Lower relative detection limits for Cd in urine can be attained if the analytical situation demands it.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aluminum determined in plasma and urine by atomic absorption spectroscopy with a transversely heated graphite atomizer furnace.

We compared a stabilized-temperature L'vov platform furnace containing an end-heated graphite atomizer (HGA) and transverse Zeeman background-correction system with a side-heated furnace system (transversely heated graphite atomizer; THGA) containing a longitudinal Zeeman background-correction system for the determination of aluminum in plasma and urine. The regression statistics for the correl...

متن کامل

Direct-calibration method for determination of aluminum in serum is comparable with the protein-precipitation technique.

We compared results by two methods for serum Al determination: matrix modification with direct calibration in a stabilized-temperature platform furnace (Clin Chem 28, 2139, 1982) and a technique involving extraction with nitric acid before atomic absorption spectrometry (Clin Chem 30, 1216, 1984). The two methods gave similar results with use of either a deuterium or a Zeeman system of backgrou...

متن کامل

Direct Determination of Selenium in Blood and Urine Samples by Platform Furnace Atomic Absorption Spectrometry

The problems encountered in platform AAS determinations of selenium in biological fluids were recently reported by Carnrick et al. [1]. The presence of phosphates produces a spectral interference for the selenium determination at 196.0 nm, avoided by using Zeeman background correction. On the other hand, Hoenig and Van Hoeyweghen show that spectral interference of phosphates in animal tissues m...

متن کامل

Improved determination of aluminum in serum and urine with use of a stabilized temperature platform furnace.

This method for determining aluminum in serum and urine is essentially free from matrix interference and gives a linear response with concentration to at least 500 micrograms/l. Use of a stabilized temperature platform (L'vov platform, Perkin-Elmer Corp.) to approach a "steady-state" temperature, addition of matrix modifiers [especially Mg(NO3)2], and the use of peak area integration all helped...

متن کامل

Determination of cadmium in urine by graphite-furnace atomic absorption spectroscopy.

A simple procedure for graphite-furnace atomic absorption analysis of cadmium in urine, based on the use of a temperature-controlled heating unit, is described. The temperature of the carbon rod is measured by resistance and controlled by electronic feedback. We studied the influence of various heating times and temperatures of ashing and atomization, as well as suitable diluents. Urine samples...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 1983