Monte Carlo simulation of expected outcomes with the AcrySof® toric intraocular lens

نویسندگان

  • Warren Hill
  • Richard Potvin
چکیده

BACKGROUND To use a Monte Carlo simulation to predict postoperative results with the AcrySof Toric lens, evaluating the likelihood of over- or under-correction using various toric lens selection criteria. METHODS Keratometric data were obtained from a large patient population with preoperative corneal astigmatism <= 2.50D (2,000 eyes). The probability distributions for toric marking accuracy, surgically induced astigmatism and lens rotation were estimated using available data. Anticipated residual astigmatism was calculated using a Monte Carlo simulation under two different lens selection scenarios. RESULTS This simulation demonstrated that random errors in alignment, surgically induced astigmatism and lens rotation slightly reduced the overall effect of the toric lens. Residual astigmatism was statistically significantly higher under the simulation of surgery relative to an exact calculation (p < 0.05). The simulation also demonstrated that more aggressive lens selection criteria could produce clinically significant reductions in residual astigmatism in a high percentage of patients. CONCLUSION Monte Carlo simulation suggests that surgical variability and lens orientation/rotation variability may combine to produce small reductions in the correction achieved with the AcrySof Toric IOL. Adopting more aggressive lens selection criteria may yield significantly lower residual astigmatism values for many patients, with negligible overcorrections. Surgeons are encouraged to evaluate their AcrySof Toric outcomes to determine if they should modify their individual lens selection criteria, or their default surgically induced astigmatism value, to benefit their patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive lens exchange using SN60T5 AcrySof Toric intraocular lens in stage 2 keratoconus

This is a case report of a 45-year-old anisometropic woman with stage 2 keratoconus submitted to refractive lens exchange employing SN60T5 AcrySof Toric intraocluar lens on her left eye. Phacoemulsification followed by proper lens implantation was accomplished successfully. On postoperative period, favorable refractive and visual outcomes were obtained. The use of toric intraocular lenses may b...

متن کامل

Results of the AcrySof Toric intraocular lenses implantation

BACKGROUND The expectations of post-removal cataract surgery patients are extremely high, and best vision acuity is expected. The best refractive results are influenced by two factors - cataract surgical removal and the corneal astigmatism correction. Currently, the two most often applied corneal astigmatism removal methods are laser surgery and toric intraocular lens implantation, with the lat...

متن کامل

Cataract Surgery in Eyes with Low Corneal Astigmatism: Implantation of the Acrysof IQ Toric SN6AT2 Intraocular Lens

PURPOSE To assess the refractive and visual outcomes following cataract surgery and implantation of the AcrySof IQ Toric SN6AT2 intraolcular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients with low corneal astigmatism. METHODS This study is a retrospective, consecutive, single surgeon series of 98 eyes of 88 patients (with low preoperative corneal astigmatism) undergoin...

متن کامل

Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses.

PURPOSE To prospectively compare the early rotational stability of AcrySof SN60T toric intraocular lenses (IOLs) with that in a retrospective series of AA4203 toric IOLs. SETTING Private practice, Los Altos, California, USA. METHODS One hundred consecutive eyes with an AcrySof SN60T(3, 4, or 5) toric IOL were compared with a consecutive series of 90 AA4203 (TL or TF) toric IOLs. The same su...

متن کامل

Toric intraocular lens orientation and residual refractive astigmatism: an analysis

PURPOSE To analyze intraocular lens (IOL) orientation data from an online toric back-calculator (astigmatismfix.com) for determining if differences were apparent by lens type. METHODS A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis. RESULTS Of 12,812 total validated calculation records, 8,229 included intend...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Ophthalmology

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008