Final Report on the Key Comparison CCM.P-K4.2012 in Absolute Pressure from 1 Pa to 10 kPa.

نویسندگان

  • Jacob Ricker
  • Jay Hendricks
  • Thomas Bock
  • Pražák Dominik
  • Tokihiko Kobata
  • Jorge Torres
  • Irina Sadkovskaya
چکیده

The report summarizes the Consultative Committee for Mass (CCM) key comparison CCM.P-K4.2012 for absolute pressure spanning the range of 1 Pa to 10 000 Pa. The comparison was carried out at six National Metrology Institutes (NMIs), including National Institute of Standards and Technology (NIST), Physikalisch-Technische Bundesanstalt (PTB), Czech Metrology Institute (CMI), National Metrology Institute of Japan (NMIJ), Centro Nacional de Metrología (CENAM), and DI Mendeleyev Institute for Metrology (VNIIM). The comparison was made via a calibrated transfer standard measured at each of the NMIs facilities using their laboratory standard during the period May 2012 to September 2013. The transfer package constructed for this comparison preformed as designed and provided a stable artifact to compare laboratory standards. Overall the participants were found to be statistically equivalent to the key comparison reference value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Method of Traceability for a Fpg8601 Force Balanced Piston Gauge to Define Pressures in the Range from 1 Pa to 15 Kpa in Gauge and Absolute Measurement Modes

 The FPG8601 has become an important reference for many primary measurement laboratories in a pressure range from approximately 1 Pa to 15 kPa in both gauge and absolute measurement modes. The FPG8601 measurement range spans the gap between the traditional measurement regimes of ‘pressure’ and ‘vacuum’, a range where other primary pressure standards either do not exist or do not have uncertain...

متن کامل

Design of High Sensitivity and Linearity Microelectromechanical Systems Capacitive Tire Pressure Sensor using Stepped Membrane

This paper is focused on a novel design of stepped diaphragm for MEMS capacitive pressure sensor used in tire pressure monitoring system. The structure of sensor diaphragm plays a key role for determining the sensitivity of the sensor and the non-linearity of the output.First the structures of two capacitive pressure sensors with clamped square flatdiaphragms, with different thicknesses are inv...

متن کامل

Using the Genetic Algorithm based on the Riedel Equation to Predict the Vapor Pressure of Organic Compounds

In this paper, a genetic algorithm (GA) has been used to predict the vapor pressure of pure organic compounds based on Riedel equation. Initially, the coefficients of Riedel equation were optimized. Then, a new term was added to the original Riedel equation to reduce error of the model in prediction of vapor pressures of pure materials. 110 components at two different pressures (10 and 100 kPa)...

متن کامل

Accuracy of venous blood oxygen pressure depends on arterial blood oxygen pressure.

I read with interest the article by REES et al. [1]. Their data on 40 patients with chronic lung disease supports the use of peripheral venous blood for an estimate of the arterial oxygen tension (Pa,O 2) in a vast majority of patients. They also address this issue in a similar study [2]. They found that mean Pa,O 2 was not clinically larger than the peripheral venous oxygen tension (0.83¡4 mmH...

متن کامل

Retinoic Acid Syndrome: A Case Report and Review

Background: The treatment of acute promyelocy!c leukemia with all-trans-re!noic acid (ATRA) some!mes results in a syndrome characterized by fever, respiratory distress, weight gain, pleural or pericardial effusion, and pulmonary infiltrates. We report the major clinical and radiologic features of ATRA syndrome. Materials and Methods: In the past, occasional case reports and literature pertainin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Metrologia

دوره 54 Technical Suppl  شماره 

صفحات  -

تاریخ انتشار 2017