Performance of the Hitachi 705 evaluated.

نویسندگان

  • P Douville
  • J C Forest
چکیده

We evaluated a new discrete analyzer, the Hitachi 705. The instrument can process sequentially as many as 19 different enzymes or other analytes, with a throughput of 180 tests per hour. We evaluated the spectrophotometer, the sample and reagent probes, and the performance for 11 assays: creatine kinase, aspartate aminotransferase, alkaline phosphatase, gamma-glutamyltransférase, amylase, glucose, urea nitrogen, creatinine, albumin, calcium, and phosphorus. The total imprecisions (within-day plus day-to-day component of imprecision) (CV) were: for the photometer (six concentrations of potassium dichromate), 0.14 to 0.4%; for the serum probe (55 to 20 microL), 0.4 to 1.0%; for the reagents probes (50 to 350 microL), 0.3 to 1.2%; for the enzymatic procedures, 2.0 to 8.0%; and for the other tests (glucose, urea nitrogen, creatinine), 1.0 to 4.0%. Good linearity was obtained in the proposed range for the 11 tests, except for calcium. Comparison of the total analytical error with the medically allowable error at a decision value showed that the test results were acceptable, except for calcium and phosphorus. The instrument showed good reliability and practicability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of seven serum assays on four automatic analysers

Serum enzyme assays used on four different analysers (Hitachi 737, Hitachi 705, Cobas-bio and RA-2X) were compared by determining the activity of seven different enzymes (AST, ALT, LD, ALP, GGT, CK and AMS). Performance checks (quality control procedure) and replications (the study of the total analytic imprecision and of its components) were conducted and the methods were compared by linear re...

متن کامل

A continuous method for the estimation of adenosine deaminase catalytic concentration in pleural effusions with a Hitachi 705 discrete analyser.

An assay of adenosine deaminase activity in pleural effusions is described. For the continuous determination of adenosine deaminase, the liberated ammonia is estimated by coupling the liberated NH3 with 2-oxoglutarate. The reaction is followed by the decrease of NADH absorbance at 340 nm. The assay was optimized for a Hitachi 705 analyser, with respect to pH, adenosine concentration and glutama...

متن کامل

Laboratory evaluation of the Greiner G-400 discrete selective multichannel analyzer.

We evaluated the new Greiner G-400 selective multichannel analyzer. Thirty different tests can be run in combination profile and single-test mode at a rate between 150 and 300 tests per hour. The new photometer allows kinetic and equilibrium (endpoint) measurements. The G-400 analyzer demonstrated excellent precision, linearity, accuracy, ease of operation, and no carryover. Results for 16 diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 1983