Dual-head lithotripsy in synchronous mode: acute effect on renal function and morphology in the pig.
نویسندگان
چکیده
OBJECTIVE To assess the effect of dual-head lithotripsy on renal function and morphology in a pig model of shockwave (SW) injury, as lithotripters with two shock heads are now available for treating patients, but little information is available with which to judge the safety of treatment with dual pulses. MATERIALS AND METHODS A dual-head electrohydraulic lithotripter (Duet, Direx Corp., Natick, MA, USA) was used to treat the lower renal pole of anaesthetized pigs with a clinical dose of SWs (2400 dual SWs; 10 kidneys) delivered in synchronous mode, i.e. both heads fired simultaneously. For comparison, pigs were treated with either 2400 SWs (12 kidneys) or 4800 SWs (eight) with a conventional electrohydraulic lithotripter (HM3, Dornier, Wessling, Germany). RESULTS Dual-pulse SW treatment with the Duet lithotripter caused a decline in the mean (sd) glomerular filtration rate (GFR) of 4.1 (1.9) mL/min, with a trend for the effective renal plasma flow (RPF), at 31 (19) mL/min, to also decrease. These changes in renal haemodynamics were similar to the decreases in GFR and RPF in response to treatment with the HM3 lithotripter with 2400 SWs, at 4.8 (0.8) and 32 (10) mL/min, respectively, or 4800 SWs, at 5.4 (1.0) and 68 (14) mL/min, respectively. Linear association analysis showed that the functional response to dual-pulse SWs was more variable than with conventional SWs. Morphological quantification of kidney damage (expressed as a percentage of functional renal volume, FRV) showed that tissue injury with 2400 paired SWs with the Duet, at 0.96 (0.39)% FRV, was similar to injury produced by either 2400 single SWs, at 1.08 (0.38)% FRV, or 4800 single SWs, at 2.71 (1.02)% FRV, with the HM3. However, morphological damage was less consistent with the Duet (measurable in only five of eight kidneys) than that with the HM3 (measurable in all 12 kidneys). Acoustic output and the timing of dual SWs in synchronous mode increased in variability as the electrodes aged, affecting the amplitude and targeting of focal pressures. CONCLUSION With the caveat that variability in the timing of dual SWs will unpredictably alter the distribution of SW energy within the kidney, this study shows that a clinical dose of dual-head SWs delivered in synchronous mode elicits a renal response similar to, but more variable than, that with a clinical dose of SWs from a conventional electrohydraulic lithotripter.
منابع مشابه
Effect of aminophylline on renal function of brain injury patients with acute renal failure admitted to the intensive care unit
Introdution: Acute renal failure is a common complication in the brain injury patients. Released adenosine in injury can reduce renal glomerular filtration. Aminophylline is an inhibitor of releasing adenosine. So, this study aimed to evaluate the effect of intravenous aminophylline in renal function of brain-injured patients with acute renal failure admitted to the intensive care unit. Method...
متن کاملA Thorough Comparative Analysis of PI and Sliding Mode Controllers in Permanent Magnet Synchronous Motor Drive Based on Optimization Algorithms
In this paper, the speed tracking for permanent magnet synchronous motor (PMSM) in field oriented control (FOC) method is investigated using linear proportional-integral (PI) controller, sliding mode controller (SMC) and its advanced counterparts. The advanced SMCs considered in this paper are fuzzy SMC (FSMC) and sliding mode controller with time-varying switching gain (SMC+TG) which can effec...
متن کاملتحلیل عملکرد حالت دائم ماشین دوتحریکه بدون جاروبک
Brushless doubly fed machine (BDFM) is indeed an induction machine which has two windings in the stator and a cage rotor with a special design. Due to absence of brushes and slip rings, this machine is considered for the applications needs high reliability, such as wind turbines. In this paper, stead state performance of BDFM in synchronous mode of operation, the most interesting mode of operat...
متن کاملCystone, a well-known herbal formulation improves renal function in rats with acute renal failure (ARF) induced by Glycerol intoxication
The present study was aimed to evaluate the beneficial effect of Cystone syrup in an experimental model of glycerol-induced acute renal failure (ARF) in rats. Biochemical parameters, kidney weight and histopathological evaluation were performed to conclude the beneficial effect of Cystone syrup. Administration of single dose of 50% v/v glycerol (8ml/kg.i.m) caused severe renal dysfunction assoc...
متن کاملThe effect of discharge voltage on renal injury and impairment caused by lithotripsy in the pig.
The present study was designed to determine the effects of shock wave voltage (kV) on lesion size and renal function induced by shock wave lithotripsy (SWL) in the 6- to 8-wk-old pig. Each SWL-treated pig received 2000 shock waves at 12, 18, or 24 kV to the lower pole calyx of one kidney. A group of sham SWL pigs served as time controls. Bilateral GFR, renal plasma flow (RPF), and para-aminohip...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BJU international
دوره 99 5 شماره
صفحات -
تاریخ انتشار 2007